    Prostar GridSolar 3 phase grid tie pv inverter 6KW for renewable energy systems

    • Origin:Guangdong, China
    • Brand:Prostar or OEM/ODM
    • Model:GridSolar GIT8K
    • Size:480×550×180mm
    • Weight:25.0 Kgs

    Prostar GridSolar GIT6K PV inverters are transformerless inverters with efficiency of up to 98%. Multi-MPPT inputs provides higher flexibility for the project installation.

    1. Description
    2. Specification
    3. Applications
    4. Download

    Prostar GridSolar GIT6K PV inverters are transformerless inverters with efficiency of up to 98%. Multi-MPPT inputs provides higher flexibility for the project installation. Stainless steel housing and IP65 protection guarantee use both indoor and outdoor for long. The series inverters are ideally suited for medium and commercial PV projects of up to MW range.

    GridSolar 3 phase grid tie pv inverter 6KW

    Embedded with two smart MPP trackers, Prostar GridSolar PV inverters can operate at their optimum power output voltage even under variety of weather conditions. To ensures your customers an optimum returns, Prostar GridSolar PV inverters also allow a wide input voltage range to generate maximum 96% eciency. Besides, it als offers user-friendly design and modulized electric design. Bundled with monitoring software, Prostar GridSolar PV inverters can help users to monitor and calculate the accurate saving energy.

    Proudct Features

    Leading technology
    ■ Max. efficiency 98.0%
    ■ MPPT accuracy up to 99.9% efficiency
    ■ Compliant with VDE-AR-N 4105

    User-friendly
    ■ 5 inch LCD display with comprehensive information
    ■ Embedded webserver monitoring
    ■ Easy installation

    Flexible
    ■ Multi-country configuration
    ■ RS485 / Ethernet / Wi-Fi communication
    ■ Wide range of DC input voltage
    ■ IP65 for indoor and outdoor


    Grid tie Inverter Characteristics

     
    Rated output power: This value will be provided in watts or kilowatts. For some inverters, they may provide an output rating for different output voltages. For instance, if the inverter can be configured for either 240 VAC or 208 VAC output, the rated power output may be different for each of those configurations.
     
    Output voltage(s): This value indicates to which utility voltages the inverter can connect. For smaller inverters that are designed for residential use, the output voltage is usually 240 VAC. Inverters that target commercial applications are rated for 208, 240, 277, 400, or 480 VAC and may also produce three phase power.
     
    Peak efficiency: The peak efficiency represents the highest efficiency that the inverter can achieve. Most grid-tie inverters on the market as of July 2009 have peak efficiencies of over 94%, some as high as 96%. The energy lost during inversion is for the most part converted into heat. This means that in order for an inverter to put out the rated amount of power it will need to have a power input that exceeds the output. For example, a 5000 W inverter operating at full power at 95% efficiency will require an input of 5,263 W (rated power divided by efficiency). Inverters that are capable of producing power at different AC voltages may have different efficiencies associated with each voltage.
     
    CEC weighted efficiency: In contrast to peak efficiency, this value is an average efficiency and is a better representation of the inverter's operating profile. Inverters that are capable of producing power at different AC voltages may have different efficiencies associated with each voltage.
     
    Maximum input current: This is the maximum amount of direct current that the inverter will use. If a DC power source, such as a solar array, produces an amount of current that exceeds the maximum input current, that current will not be used by the inverter.
     
    Maximum output current: The maximum output current is the maximum continuous alternating current that the inverter will supply. This value is typically used to determine the minimum current rating of the over-current protection devices (e.g., breakers and fuses) and disconnects required for the output circuit. Inverters that are capable of producing power at different AC voltages will have different maximum outputs for each voltage.
     
    Peak power tracking voltage: This represents the DC voltage range in which the inverter's maximum point power tracker will operate. The system designer must configure the strings optimally so that during the majority of the year, the voltage of the strings will be within this range. This can be a difficult task since voltage will fluctuate with changes in temperature.
     
    Start voltage: This value is not listed on all inverter datasheets. The value indicates the minimum DC voltage that is required in order for the inverter to turn on and begin operation. This is especially important for solar applications, because the system designer must be sure that there is a sufficient number of solar modules wired in series in each string to produce this voltage. If this value is not provided by the manufacturer, system designers typically use the lower band of the peak power tracking voltage range as the inverter's minimum voltage.
     
    IPxx rating: The Ingress Protection rating or IP Code classifies and rates the level of protection provided against the ingress of solid foreign objects (first digit) or water (second digit), a higher digit means greater protection. 
     
    Warranty
    Five years warranty after the date of delivery.
     
    Payment Terms
    Terms of payment is T/T or L/C. 30% deposit before production, 70% balance before shipment.
     

    Contact Information

     

    Contact Person: Mr. Orson

    Email: inquiry@prostarsolar.netprostarsolar@sina.com

    Skype: orsonz.prostar

    Mobile: (+86)-13827733783 (whatsApp)

    Website: www.prostarsolar.net

     

       Scan Wechat to talk with Orson directly!   

    Scan Wechat to talk with Orson




    Tag:  Prostar GridSolar 3 phase grid tie inverter grid tie inverter grid tie inverter 5KW grid tie pv inverter renewable energy systems renewable energy pv inverter 6kw 6kw inverter 6kw
    TypeGridSolar GIT5KGridSolar GIT6KGridSolar GIT8KGridSolar GIT10K
    Input (DC)
    Max. DC Power [W]52006300820010400
    Max. DC Voltage [V]1000
    MPPT Voltage Range of Full Load  [V]240-800320-800340-800430-800
    Nominal DC Voltage [V] 600
    Start  Voltage[V]   300
    Min. DC Voltage[V] 200
    Max. DC Input Current PV1 / PV2 [A]12/1212/12
    Number of MPPT 2
    String(s)per MPPT1/12/1
    DC SwitchOptional
    Output (AC)
    Rated AC Power [W](@230V,50Hz)50006000800010000
    Max. AC Apparent Power [VA]50006000800010000
    Rated AC Current[A]7.28.711.614.5
    Max. AC Current [A]8.19.712.916.1
    Nominal AC  voltage/ range3/N/PE, 220/380V,230/400V,240/415V;180V-280V/312V-485V
    Grid frequency/ range50Hz,60Hz /44Hz-55Hz,54-65Hz
    Power factor,adjustable0.9 leading~0.9 lagging
    Total Harmonic Distortion (THDi) < 2% (at nominal power)
    Feed-in Phase / Connection Phase3 /3
    Efficiency
    Max. Efficiency97.9%97.9%97.9%98.0%
    Euro Efficiency (at 640Vdc)97.3%97.3%97.3%97.5%
    MPPT Accuracy>99.5%
    Protection
    Internal Over-voltage ProtectionIntegrated
    DC Insulation MonitoringIntegrated
    DCI MonitoringIntegrated
    GFCI MonitoringIntegrated
    Grid Monitoring Integrated
    AC Short Circuit Current ProtectionIntegrated
    Thermal ProtectionIntegrated
    Anti-island protection monitoringAFD
    Interface
    DC ConnectionMC4/H4
    LCD DisplayGraphic LCD Display, Backlight, Inverter Parameter and Data Display
    Display LanguageMulti Language
    Datalogger & CommunicationRS485 (Standard), Ethernet (Webserver embedded), WiFi(Optional), 
    General Data
    TopologyTransformerless
    Consumption at Night [W] <1
    Consumption at Standby [W] <12
    Operating Temperature Range -20°C to +60°C (45°C to 60°C with derating)
    Cooling MethodNatural ConvectionFans
    Ambient Humidity0% to 95% Non-condensing
    AltitudeUp to 2000m (without power derating)
    Noise [dBA]<30<40
    Ingress Protection IP65 (Indoor & Outdoor Installation)
    Mounting Rear Panel
    Dimensions (W*H*D) [mm]480×550 ×180
    Weight [kg] 25
    Standard Warranty [Year]5 (standard) /10/15/20/25 (Optional)
    CertificatesCE IEC62109-1/2,  IEC61000-6-2/3, PEA/MEA,  VDE0126-1-1/A1, C10/11, G83/2, G59/2, G59/3,  EN50438, TF3.2.1, UTE C15-712-1, IEC62116, IEC61727, AS4777.2, AS4777.3, AS3100



    Tag:  Prostar GridSolar 3 phase grid tie inverter grid tie inverter grid tie inverter 5KW grid tie pv inverter renewable energy systems renewable energy pv inverter 6kw 6kw inverter 6kw