    Prostar PowerSolar series inverters are equipped with MPPT solar charge controller to maximize and regulate DC power from the solar array for the charging the battery bank. Transformerless design provides reliable power conversion in compact size. Besides, it’s worry-free to start up motor-type loads such as refrigerators, motors, pumps, compressors and laser printers as well as electronic loads like TV’s, Computers, power tool and battery chargers.

    1. Description
    2. Specification
    3. Applications
    4. Download

    Prostar PowerSolar 48V 3KVA 2400 watt pure sine inverter for solar electricity systems

    Prostar PowerSolar off-grid inverter is a multi-function inverter/charger, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

    Overview

    Prostar PowerSolar series inverters are equipped with MPPT solar charge controller to maximize and regulate DC power from the solar array for the charging the battery bank. Transformerless design provides reliable power conversion in compact size. Besides, it’s worry-free to start up motor-type loads such as refrigerators, motors, pumps, compressors and laser printers as well as electronic loads like TV’s, Computers, power tool and battery chargers.

    48V 3KVA 2400 watt pure sine inverter

    Features

    1. Pure sine wave inverter

    2. Built-in MPPT solar charge controller

    3. Selectable input voltage range for home appliances and personal computers

    4. Selectable charging current based on applications

    5. Configurable AC/Solar input priority via LCD setting

    6. Compatible to mains voltage or generator power

    7. Auto restart while AC is recovering

    8. Overload and short circuit protection

    9. Smart battery charger design for optimized battery performance

    10. Cold start function

    11. Parallel operation with up to 6 units only available for 4KVA/5KVA

    12. Optional Remote Control Panel available

    Basic System Architecture

    The following illustration shows basic application for this inverter/charger. It also includes following devices to have a complete running system:

    Consult with your system integrator for other possible system architectures depending on your requirements.

    This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.

    solar electricity systems

    Note: Appliances like air conditioner need at least 2~3 minutes to restart because it’s required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer of air conditioner if it’s equipped with time-delay function before installation. Otherwise, this inverter/charger will trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner.

    Product Details

    solar inverter

    solar invertersolar inverter

    Inverter Installation

    Unpacking and Inspection

    Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package:

    • The unit x 1

    • User’s manual x 1

    • Communication cable x 1

    Preparation

    Before connecting all wirings, please take off bottom cover by removing two screws as shown below.

    Prostar PowerSolar Solar Inverter Installation       

    Mounting the Unit

    Consider the following points before selecting where to install:

    1.  Do not mount the inverter on flammable construction materials.

    2.  Mount on a solid surface

    3.  Install this inverter at eye level in order to allow the LCD display to be read at all times.

    4.  For proper air circulation to dissipate heat, allow a clearance of approx. 10 cm to the side and approx. 50 cm above and below the unit.

    5.  The ambient temperature should be between 0°C and 55°C to ensure optimal operation.

    6.  The recommended installation position is to be adhered to the wall vertically.

    7.  Be sure keep other objects and surfaces as shown in the below diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

    Prostar PowerSolar Solar Inverter Mounting               Prostar PowerSolar Solar Inverter Installation

    Battery Connection

    CAUTION: To safety operation and regulation compliance, it’s requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it’s still requested to have over-current protection installed. Please refer to typical amperage in below table as required fuse or beaker size.

    WARNING! All wiring must be performed by a qualified personnel.

    WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable and terminal size as below.

    Recommended battery cable and terminal size:

    Prostar PowerSolar Inverter battery connection cable size

    Please follow below steps to implement battery connection:

    1. Assemble battery ring terminal based on recommended battery cable and terminal size.

    2. Units support 24VDC or 48VDC system. Connect all battery packs as units requires. It’s suggested to connect at least 100Ah capacity battery for each.

    NOTE: Please only use sealed lead acid battery or sealed GEL/AGM lead-acid battery.

    3. Insert the ring terminal of battery cable flatly into battery connector on the inverter and make sure the bolts are tightened to a torque of 2-3 Nm. Make sure polarity at both the battery and the inverter/charge is correctly connected and ring terminals are tightly screwed to the battery terminals.

    PowerSolar Solar Inverter Battery Connection

    AC Input/Output Connection

    CAUTION!!  Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 10A for 1KVA, 20A for 2KVA, 32A for 3KVA.

    CAUTION!!  There are two terminal blocks with “IN” and “OUT” markings. Please DO NOT mis-connect input and output connectors.

    WARNING!  All wiring must be performed by a qualified personnel.

    WARNING!  It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.

    PowerSolar Solar Inverter AC Cable Size

    Please follow below steps to implement AC input/output connection:

    1. Before making AC input/output connection, be sure to open DC protector or disconnector first.

    2. Remove insulation sleeve 10mm for six conductors 1K/2K/3KVA. And shorten phase L and neutral N conductor 3 mm.

    3. Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (ground line) first.

    PowerSolar Inverter AC Input Connection

    4. Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws. Be sure to connect PE protective conductor (Ground Line) first.

    PowerSolar Inverter AC Output Connection

    5. Make sure the wires are securely connected.

    PV Connection

    CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.

    WARNING! All wiring must be performed by a qualified personnel.

    WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.

    PowerSolar Inverter PV Connection Cable Size

    Please follow below steps to implement PV module connection:

    1. Remove insulation sleeve 10 mm for positive and negative conductors.

    2. Check correct polarity of connection cable from PV modules and PV input connectors. Then, connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.

    3. Make sure the wires are securely connected.

    PowerSolar Inverter PV Connection


    Final Assembly

    After connecting all wirings, please put bottom cover by screwing two screws as shown below.

    PowerSolar Inverter final Installation

    OPERATION

    PowerSolar Inverter power off on

    Once the unit has been properly installed and the batteries are connected well, simply press On/Off switch (located on the button of the case) to turn on the unit.

    Warranty

    One year warranty after the date of delivery.

    Payment Terms

    Terms of payment is T/T or L/C. 30% deposit before production, 70% balance before shipment.

    Contact Information

    Contact Person: Mr. Orson

    Email: inquiry@prostarsolar.net; prostarsolar@sina.com; orsonz.prostar@gmail.com

    Skype: orsonz.prostar

    Mobile: (+86)-13827733783 (whatsApp)

    Website: www.prostarsolar.net

     

       Scan Wechat to talk with Orson directly!   

    Scan Wechat to talk with Orson


    Tag:  Prostar inverter PowerSolar 2400 watt pure sine inverter 3KVA solar inverter solar electricity systems 48V inverter PowerSolar Inverter
    ModelPowerSolar
    PIS1K-24
    PowerSolar
    PIS1K-48
    PowerSolar
    PIS2K-24
    PowerSolar
    PIS3K-24
    PowerSolar
    PIS3K-48

    PowerSolar

    PIS4K-48

    PowerSolar

    PIS5K-48

    RATED POWER1KVA/0.8KW1KVA/1KW2KVA/1.6KW3KVA/2.4KW3KVA/2.4KW4KVA/3.2KW5KVA/4KW
    INPUT
    Voltage120 VAC or 230 VAC230 VAC
    Selectable Voltage Range95-140 VAC or 170-280 VAC (For Personal Computers)
    65-140 VAC or 90-280 VAC (For Home Appliances)
    170-280 VAC (For Personal Computers)
    90-280 VAC (For Home Appliances)
    Frequency Range50 Hz/60 Hz (Auto sensing)
    OUTPUT
    AC Voltage Regulation (Batt. Mode)110/120 VAC ± 5% (User
    selectable) or 230VAC ± 5%
    230VAC ± 5%
    Surge Power2000VA4000VA6000VA8000VA10000VA
    Efficiency (Peak)90%-93%93%
    Transfer Time10 ms (For Personal Computers); 20 ms (For Home Appliances)
    WaveformPure sine wave
    BATTERY & AC CHARGER
    Battery Voltage24 VDC48 VDC24 VDC24 VDC48 VDC48 VDC
    Floating Charge Voltage27 VDC54 VDC27 VDC27 VDC54 VDC54 VDC
    Overcharge Protection31 VDC62 VDC31 VDC31 VDC62 VDC60 VDC
    SOLAR CHARGER & AC CHARGER
    Maximum PV Array Power600 W900 W600 W600 W900 W3000 W
    MPPT Range @ Operating Voltage30VDC~ 66VDC60VDC~ 88VDC30VDC ~ 66VDC30VDC ~ 66VDC60VDC ~ 88VDC60VDC ~
    115VDC
    Maximum PV Array Open Circuit Voltage75VDC102VDC75VDC75VDC102VDC145VDC
    Maximum Solar Charge Current25A18 A25A25A18A60A
    Maximum AC Charge Current10 A / 20 A10 A / 15 A20 A or 30 A20 A or 30 A10 A / 15 A60 A
    Maximum Charge Current25A18 A30A30A18A120A
    Maximum Efficiency98%
    Standby Power Consumption2 W
    PHYSICAL
    Dimension, D x W x H (mm)100 x 272 x 355140 x 295 x 540
    Net Weight (kgs)6.87.07.412.513.5
    OPERATING ENVIRONMENT
    Humidity5% to 95% Relative Humidity(Non-condensing)
    Operating Temperature0°C - 55°C
    Storage Temperature-15°C - 60°C
    * There are charging current selection only available for 230VAC system.
    Product specifications are subject to change without further notice