High Frequency Online UPS 2KVA | 36Vdc | 220Vac/230Vac/240Vac @50Hz/60Hz | Without battery inside | Dimension: 397x145x220mm
Prostar PHT1102 single phase uninterruptible power supply ups 2kva is double-conversion high frequency online UPS with a output power factor 0.8. Specifically designed for operation in poor power areas. It’s ideal for ATMs, banking and other business critical applications. Users also can adjust charging current from 1A to 6A according to different applications.
Prostar PHT1102 single phase uninterruptible power supply ups 2kva also have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relate contact cards.
To avoid damage and protect your equipments and IT network, install an Uninterruptible Power Supply system like UPS 10kva as it is the safest approach to ensure high quality electrical supply.
1.True double-conversion online UPS
A true double conversion UPS will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications.
2. Output power factor 0.8
Compared to the online UPS in the current market, Venus series UPS provides better output power factor up to 0.8. It offers higher performance and effciency for critical applications.
3. Wide input voltage range (110V-300V)
Venus series UPS can still provide stable power to connected devices under unstable power environments.
4. 50/60 Hz Frequency Converter Mode
Lock output frequency at 50Hz or 60Hz to suit power sensitive equipments.
5. LCD + LED status display
Quickly understand unit and power status with visual indicators.
6. Audible alarms
Provides notification of changing utility power and UPS power conditions.
7. Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
8. Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
9. SmartSlot
Customize UPS capabilities with management cards.
10. Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
11. Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
12. Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
13. Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
14. Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
15. Cold-start capable
Provides temporary battery power when the utility power is out.
Shown 1. High Frequency Online UPS 2KVA – Front
Shown 2. High Frequency Online UPS 2KVA – Rear
Shown 3. High Frequency Online UPS 2KVA – Left Side
Shown 4. High Frequency Online UPS 2KVA – Right Side
Shown 5. High Frequency Online UPS Monitoring & Accessory
Now Become A Partner with Prostar!
MODEL | PHT1102 | |
CAPACITY | 2000VA / 1600W | |
Battery Voltage | 72V | |
Size, D X W X H (mm) | 397 X 145 X 220 | |
Net Weight (kgs) | 6.8 | |
INPUT | ||
Voltage Range | Low Line Transfer | 160VAC/140VAC/120VAC/110VAC±5% |
Low Line Comeback | 175VAC/155VAC/135VAC/125VAC ± 5 % | |
High Line Transfer | 300 VAC ± 5 % | |
High Line Comeback | 290 VAC ± 5 % | |
Frequency Range | 40Hz ~ 70 Hz | |
Phase | Single phase with ground | |
Power Factor | ≧ 0.99 @ nominal voltage (input voltage) | |
OUTPUT | ||
Output voltage | 200/208/220/230/240VAC | |
AC Voltage Regulation | ± 1% (Batt. Mode) | |
Frequency Range(Synchronized Range) | 47Hz ~ 53 Hz @ 50Hz | |
57Hz ~ 63 Hz @ 60Hz | ||
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | |
Overload | 105%~110%: UPS shuts down after 10 min at battery mode or transfer to bypass when the utility is normal 110%~130%: UPS shuts down after 1min at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down after 3seconds at battery mode or transfer to bypass when the utility is normal |
|
Current Crest Ratio | 3:1 | |
Harmonic Distortion | ≦ 3 % THD (Linear Load);≦ 5% THD (Non-linear Load) | |
Transfer Time | AC Mode to Batt. Mode | 0 ms |
Inverter to Bypass | 4 ms | |
Waveform (Batt. Mode) | Pure Sine Wave | |
EFFICIENCY | ||
AC Mode | 89% | |
Battery Mode | 87% | |
BATTERY | ||
Battery Type | Depending on applications | |
Battery Numbers | Depending on applications | |
Recharge Time | Depending on applications | |
Charging Current | 1.0A/2.0A/4.0A/6.0 A | |
Charging Voltage | 82.1VDC ± 1% | |
ENVIRONMENT | ||
Operation Humidity | 20-90 % RH @ 0- 40°C (non-condensing) | |
Noise Level | Less than 50dBA @ 1 Meter | |
MANAGEMENT | ||
Smart RS-232 or USB | Windows® 2000/2003/XP/Vista/2008、Windows® 7/8、Linux、Unix、MAC | |
Optional SNMP | Power management from SNMP manager and web browser |