Lead Acid Battery | 12V 4.5AH | 20 Hour Rate | Dimension: 90x70x101x107mm
GP4.5-12 valve regulated 12v 4.5 ah battery for alarm security system uses a state of the art, heavy-duty, calcium-alloy grid that provides exceptional performance and service life in both float and cyclic applications.
The grid structure of the lead acid battery is made from a lead alloy. Pure lead is too soft and would not support itself, so small quantities of other metals are added to get the mechanical strength and improve electrical properties.
Valve regulated 12v 4.5 ah battery is an Absorbent Glass Mat (AGM) technology with a valve regulated design, that can be used in enclosed and indoor environments without leaking or maintenance, providing a superior performance for thousands of models.
Nominal Voltage | 12V | ||
Nominal Capacity (20 hour rate) | 4.5Ah | ||
Capacity
25℃(77°F) |
10 hour rate (0.43A) | 4.3Ah | |
5 hour rate (0.80A) | 4.0Ah | ||
1 hour rate (2.97A) | 2.97Ah | ||
Internal Resistance | Full Charged Battery 25℃ | ≤32mΩ | |
Capacity affected by Temperature
(10 hour ) |
40℃ (104°F) | 102% | |
25℃ (77°F) | 100% | ||
0℃ (32°F) | 85% | ||
-15℃ (5°F) | 65% | ||
Self-Discharge
25℃(77°F) Capacity |
after 3 month storage | 90% | |
after 6 month storage | 80% | ||
after 12 month storage | 62% | ||
Charge (Constant Voltage) 25℃(77°F) | Float | Initial Charging Current Less than1.35A
Voltage 13..6-13.8V |
|
Cycle | Initial Charging Current Less than1.35A
Voltage 14.4-15.0V |
Battery Dimensions | Length | 90mm |
Width | 70mm | |
Height | 101mm | |
Total Height | 107mm | |
Box Dimensions | Length | 389mm |
Width | 200mm | |
Height | 147mm | |
Quantity Per Box | 10 pcs per box | |
Net weight Per Cell | 1.38 kg±50g | |
Net weight Per Box | 13.8kg | |
Gross Weight | 14.2kg |
Discharge Constant Current per Cell (Amperes at 77°F25°C)
F.V/Time | 5min | 10min | 15min | 30min | 45min | 1h | 2h | 3h | 5h | 8h | 10h | 20h |
16.50 | 14.85 | 9.90 | 7.45 | 4.95 | 3.47 | 2.97 | 1.86 | 1.27 | 0.85 | 0.57 | 0.47 | 0.25 |
16.20 | 14.58 | 9.72 | 7.31 | 4.86 | 3.40 | 2.92 | 1.82 | 1.25 | 0.83 | 0.56 | 0.46 | 0.24 |
15.90 | 14.31 | 9.54 | 7.18 | 4.77 | 3.34 | 2.86 | 1.79 | 1.23 | 0.82 | 0.55 | 0.45 | 0.24 |
15.60 | 14.04 | 9.36 | 7.04 | 4.68 | 3.28 | 2.81 | 1.76 | 1.20 | 0.80 | 0.54 | 0.45 | 0.23 |
15.00 | 13.50 | 9.00 | 6.77 | 4.50 | 3.15 | 2.70 | 1.69 | 1.16 | 0.77 | 0.52 | 0.43 | 0.23 |
Discharge Constant Power per Cell (Watts at 77°F 25°C)
F.V/Time | 5min | 10min | 15min | 30min | 45min | 1h | 2h | 3h | 5h | 8h | 10h | 20h |
1.60V | 28.59 | 19.06 | 14.34 | 9.53 | 6.67 | 5.72 | 3.57 | 2.45 | 1.63 | 1.10 | 0.91 | 0.48 |
1.65V | 28.07 | 18.71 | 14.08 | 9.36 | 6.55 | 5.61 | 3.51 | 2.40 | 1.60 | 1.08 | 0.89 | 0.47 |
1.70V | 27.55 | 18.36 | 13.82 | 9.18 | 6.43 | 5.51 | 3.44 | 2.36 | 1.57 | 1.06 | 0.87 | 0.46 |
1.75V | 27.03 | 18.02 | 13.56 | 9.01 | 6.31 | 5.41 | 3.38 | 2.32 | 1.54 | 1.04 | 0.86 | 0.45 |
1.80V | 25.99 | 17.33 | 13.04 | 8.66 | 6.06 | 5.20 | 3.25 | 2.23 | 1.48 | 1.00 | 0.82 | 0.43 |