MPS60K 3 phase modular ups redundant hot swappable power module 60kw

3 Phase Modular UPS Power Modular | 60KVA / 60KW | 3 Phases 4 Wires | 380Vac/400Vac/415Vac@50Hz/60Hz | +/-240Vdc | Pure Sine Wave

SKU: MPS60K Category:

MPS60K 3 phase modular ups redundant hot swappable power module 60kw provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

The hot-swappable Power Modules allow quick maintenance and expansion. A latch located on the front of each module fixes and locks the module in its assigned slot. Each Power Module has an LED indicator to show its operation status.

Thanks to its modular and scalable design as well as its hot-swappable functionality, 3 phase power module 60kw can start with a basic configuration of just 60 kVA / 60 kW and then grow gradually as required, up to 300 kVA. this power module offers input PF >0.99 and input THDi <3 %, even when a low percentage of load is applied.

redundant hot swappable power module 60kw

The redundant power module has independent hardware and controllability, able to operate and coordinate with other modules within the system. The control of power modules connected in parallel is decentralized in the single 60 kVA device (no centralized control system). The omission of the master/slave architecture, eliminates any possibility of a problem due to the failure of a single power module.

Power Module 60KW Features

  • Easy hot swap design
  • Output factor is 1 (kVA = kW)
  • Power module can be scalable system
  • Flexible modular design
  • Automatic restart of loads after UPS shutdown
  • Input Power Factor Correction
  • Predictive failure notification
  • Intelligent battery management
  • N+1 or N+x redundant parallel
  • Save time with easy and convenient remote accessibility
  • Repeatable and standardised assets to meet different configuration and architectural requirements
  • Generator compatible

Power Module Details

Modular UPS 60 kVA Power Modular Rear Panel

Power Module Rear Panel Information

Modular UPS Power Modular Switch Setting

The Articles You may Like

Cabinet Model MPS60K
Maximum Capacity 60KVA / 60KW
Phase 3-phase in / 3-phase out
Battery Voltage 240V Default, 192V/240V Selectable
Size, D X W X H (mm) 750x438x130 [3U]
Weight (Kgs) 44
INPUT
Input Voltage 380VAC/400VAC/415VAC (3Ph+N)
Voltage Range 305~477VAC at 100% Load; 208~304VAC at <70% Load
Nominal Frequency 50/60Hz(Auto Sensing)
Frequency Range 40Hz~70Hz
Power Factor >0.99 @ 100% Load, >0.98 @ 50% Load
Harmonic Distortion (THDi) < 3% @ 100% Load
OUTPUT
Nominal Voltage 380VAC/400VAC/415VAC (3Ph+N)
Voltage Regulation(Steady state) ≦±1%Typical(Balanced Load);≦±2% Typical (Unbalanced Load)
Voltage Regulation(Transient) ≦±5% Typical
Nominal Frequency 50/60Hz
Frequency Range(Synchronized) 46Hz~54Hz or 56Hz~64Hz
Power Factor 1 (kVA=kW)
Overload Capability 1 hour for 110%,10 min for 120%,1 min for 150%,200ms for >150%
Harmonic Distortion ≦1.5% THD(Linear Load);≦4% THD( Non-linear Load )
Efficiency Up to 94.5%
BATTERY/CHARGER
Nominal Voltage +/- 216V (12V x 36Pcs)
Maximum Voltage +/- 240V (12V x 40Pcs)
Minimum Voltage +/- 192V (12V x 32Pcs)
Float Charging Voltage 2.25V/Cell
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current 18A for each power module (User adjustable)
STANDARDS
Safety IEC/EN 60950-1; IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3
ENVIRONMENT
Operation Temperature 0~40°C
Relative Humidity 0~95% Non-condensing
Altitude <1000m for Nominal power
IP Class IP20