Double Conversion UPS | 10KVA / 10KW | 192Vdc | 208V/220V/230V/240V | Without battery inside
Prostar PET1110 best double conversion online ups 10kva 220v for alarm systems is affordably provides robust, reliable, compact and efficient power management solution.
PET1110 double conversion online ups 10kva is guaranteeing an efficiency of up to 95.5% and an output power factor of unity.
POWERONE UPS provides early-warning fault analysis on batteries enabling timely preventive maintenance. It Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
Best online UPS 10KVA is capable of supporting high-power loads, making it ideal for data centers, medical facilities, and other critical infrastructure that require uninterrupted power supply.
The online design of our UPS ensures that your equipment receives clean and stable power even in the event of power outages or surges. This is achieved through a double conversion process where incoming AC power is first converted to DC power and then back to AC power, providing a clean and stable sine wave output that protects your sensitive electronics and equipment from voltage fluctuations and other power disturbances.
UPS systems can be used anywhere that needs to ensure that the power keeps on following. The most common applications are where power is critical to avoid infrastructure damage, like in a data centre or manufacturing facility.
If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output. Consult your generator’s manual to see if it meets these specifications.
A battery is a device that stores energy, a UPS detects when there is no longer any power coming from the mains and switches over to the UPS batteries.
MODEL | PET1110 | |
CAPACITY | 10000VA / 10000W | |
Battery Voltage | 192VDC | |
Size, D X W X H (mm) | 395 X 190 X 330 | |
Net Weight (kgs) | 15 | |
INPUT | ||
Norminal Voltage | 208/220/230/240VAC | |
Input Voltage Range | 110-300VAC | |
Frequency Range | 50Hz:44Hz~56Hz or 60Hz:54Hz~66Hz | |
Phase | Single Phase, L+N+PE | |
Power Factor | ≧ 0.99 | |
Harmonic Distortion | ≤5% (Linear Load), ≤8% (Non-linear Load) | |
OUTPUT | ||
Output voltage | 208/220/230/240VAC | |
AC Voltage Regulation | ± 1% (Batt. Mode) | |
Frequency Range(Line Mode) | Synchronized range | |
Frequency Range (Batt. Mode) | 50 Hz or 60Hz ± 0.1% | |
Overload Capacity | AC Mode: Battery Mode: 30mins @102%-110% load 10mins @102%-110% load 10mins @110%-130% load 1min @110%-130% load 30sec @130%-150% load 10sec @110%-130% load 500ms @>150% load 500ms @>150% load |
|
Current Crest Ratio | 3:1 | |
Harmonic Distortion | ≦2% THD (Linear Load);≦5% THD (Non-linear Load) | |
Transfer Time | AC Mode to Battery Mode | 0ms |
Inverter to Bypass | 0ms | |
Waveform (Batt. Mode) | Pure Sine Wave | |
EFFICIENCY | ||
AC Mode | 95.5% | |
Battery Mode | 95.3%(192VDC), 94.8%(240VDC) | |
BATTERY | ||
Battery Type | Depending on applications | |
Battery Numbers | 16-20PCS | |
Charging Current | 5A(Default),1A-12A adjustable | |
Charging Voltage | 219.2VDC ± 1% / 274.0VDC ± 1% | |
Charging Mode | 2-stage or 3-stage | |
INDICATORS | ||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault condictions | |
ENVIRONMENT | ||
Ambient temperature | 0- 40°C | |
Operation Humidity | 20%-95% (non-condensing) | |
Storage temperature | -15~60℃ (no battery inside) | |
Altitude | <1000m ( the height above 1000m should be reduced to a maximum of 4000m.) | |
Noise Level | Less than 55dBA @ 1 Meter | |
COMMUNICATION | ||
Communication Inteface | Standard: RS232, USB; Option: Dry contact, EPO | |
Smart Slot | Optional SNMP Card |