Rack Mount UPS | 10kVA/10kW | PF 1.0 | 192Vdc | 208V/220V/230V/240V | Without battery inside
Prostar PER1110 single phase 10kva rack mount ups power supply for computer provides temporary battery power when the utility power is out.
PER1110 rack mount 10kva ups power supply protects connected loads from surges, spikes, lightning, and other power disturbances.
The UPS’s output power factor is 1.0, which means that more critical devices with higher amount of total watts can be powered by the UPS, utilizing more loads efficiently.
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
1.Smart slot 10.Maintenance bypass switch (option)
2.RS-232 port 11.Cooling fan
3.Output receptacles 12.AC Input terminal
4.Ground terminal 13.AC Output terminal
5.External battery connector 14.AC Input/Output terminal
6.Emergency power off connector (option) 15.Battery pack output circuit breaker
7.USB port 16.Battery bank
8.Input circuit breaker 17.Rack mount hole
9.AC Input socket 18.Parallel operation port (option)
Some types of UPS can be mounted either in a vertical or horizontal position and are designed properly vent in either kind of install. If you choose to install a UPS that is not approved for a vertical installation it may overheat and fail far earlier then you would expect. A UPS by it’s nature creates a lot of heat.
An uninterruptible power supply (UPS) is an electrical setup that provides power backup when the main power source fails. It protects hardware such as computers, telecommunication equipment, and other sensitive electronics.
To correctly size an uninterruptible power supply, it is important to calculate the total IT load it is to power. This can be calculated by summing the VA (Volts x Amperage) of all the individual IT devices.
MODEL | PER1110 | |
CAPACITY | 10000VA / 10000W | |
Battery Voltage | 192VDC(default) / 240VDC | |
Size, D X W X H (mm) | 440X420X88 | |
Net Weight (kgs) | 11 | |
INPUT | ||
Nominal Voltage | 208/220/230/240VAC | |
Input Voltage Range | 110-300VAC | |
Frequency Range | 50Hz:44Hz~56Hz or 60Hz:54Hz~66Hz | |
Phase | Single Phase, L+N+PE | |
Power Factor | ≧ 0.99 @ nominal voltage (input voltage) | |
Harmonic Distortion | ≤4% (Linear Load), ≤5% (Non-linear Load) | |
OUTPUT | ||
Output voltage | 208/220/230/240VAC | |
AC Voltage Regulation | ± 1% (Batt. Mode) | |
Frequency Range(Line Mode) | Synchronized range | |
Frequency Range (Batt. Mode) | 50Hz ± 0.25Hz or 60Hz ± 0.3Hz | |
Overload Capacity | 30mins @102%-110% load 10mins @110%-130% load 30sec @130%-150% load 200ms @>150% load |
|
Current Crest Ratio | 3:1 | |
Harmonic Distortion | ≦3% THD (Linear Load);≦6% THD (Non-linear Load) | |
Transfer Time | AC Mode to Battery Mode | 0ms |
Inverter to Bypass | 0ms | |
Waveform (Batt. Mode) | Pure Sine Wave | |
EFFICIENCY | ||
AC Mode | 95.5% | |
Battery Mode | 95.3% | |
BATTERY | ||
Battery Type | Depending on applications | |
Battery Numbers | 16 PCS | |
Charging Current | 5A(Default),1A-12A adjustable | |
Charging Voltage | 216VDC ± 1% | |
Charging Mode | 2-stage(CC/ Floating) or 3-stage (CC/CV/Floating) | |
INDICATORS | ||
LCD Panel | Load level, Battery level, AC mode, Battery mode, Bypass mode,and Fault conditions | |
ENVIRONMENT | ||
Ambient temperature | 0- 40°C | |
Operation Humidity | 5%-95% (non-condensing) | |
Storage temperature | -15~60℃ (no battery inside) | |
Altitude | <1000m ( the height above 1000m should be reduced to a maximum of 4000m.) | |
Noise Level | Less than 50dBA @ 1 Meter | |
COMMUNICATION | ||
Communication Interface | Standard: RS232, USB; Option: Dry contact, EPO | |
Smart Slot | Optional SNMP Card |