Hybrid Solar Inverter | 8000W | IP65 | 40VDC - 60VDC | Single Phase
Prostar PHYD8K IP65 single phase hybrid 8000w solar inverter 48v is engineered to deliver exceptional performance, adaptability, and protection.
Hybrid 8000w solar inverter 48v offers flexibility and reliability by integrating seamlessly with mains voltage or generator power. The LCD settings allow you to set charging priority among AC, solar, and generator sources, while also enabling you to tailor battery charging current and voltage to meet specific application requirements.
Designed to work seamlessly with lithium batteries, this 8000w solar inverter provides a safe and efficient means to store and utilize renewable energy. It supports the latest battery technology, making it ideal for modern solar systems.
Pure Sine Wave AC Power Output
Providing clean and stable AC power, the pure sine wave output ensures that all connected devices, including sensitive electronics, operate smoothly without risk of damage.
Dual MPPT Solar Charge Controller
Maximize energy harvest from your solar panels with dual Maximum Power Point Tracking technology.
IP65 Protection
Weather-resistant design for reliable outdoor installation, providing protection against dust and water ingress.
On/Off Grid Capability
The hybrid solar inverter offers seamless integration into both grid-connected and standalone systems, providing you with the flexibility to switch between modes as required. This dual functionality ensures that you have continuous power supply, even in the event of grid outages.
Programmable Operation Modes
Customize your system with multiple operation modes including on-grid, off-grid, and UPS.
Supply Priority Configuration
Set the priority for power supply from either the battery or the grid, allowing for customized management of your energy resources.
Adjustable Charging Parameters
Tailor the battery charging parameters according to your specific application needs directly through the LCD settings, ensuring optimal battery health and performance.
Peak Shaving
The inverter’s peak shaving feature helps manage demand charges by using stored energy during peak rate hours, reducing reliance on the grid and saving on electricity bills.
Wiring #1.
This diagram illustrates a grid system without specific requirements for electrical wiring connections.
Note: The backup PE line and earthing bar must be properly and effectively grounded. Failure to do so may result in abnormal backup function when the grid fails.
Wiring #2.
This diagram exemplifies applications where the Neutral is connected to the PE in the distribution box, such as in Australia, New Zealand, South Africa, etc. (Please adhere to local wiring regulations!)
Cost Savings
Energy Independence
Enhanced Flexibility
Customization and Control
Enhanced Power Quality
Residential Solar Systems
Commercial and Industrial Installations
Remote and Off-Grid Locations
Backup Power Systems
Peak Shaving and Energy Management
Model | PHYD8K |
PHASE | 1-phase in/1-phase out |
Max. PV INPUT POWER | 10400W |
Rated Output Power | 8000W |
Parallel Function | up to 16 units |
Dimension, D x W x H (mm) | 258x413x630 |
Net weight (kgs) | 29 |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 370VDC / 500VDC |
Start-up Voltage | 125VDC |
MPPT Voltage Range | 150VDC~425VDC |
Full load MPPT Voltage Range | 200VDC~425VDC |
Max. DC INPUT Current | 26A + 26A |
Max. DC Short-circuit Current | 44A + 44A |
No. of MPPT Trackers | 2 |
No. of String per MPPT Tracker | 2 + 2 |
GRID OUTPUT (AC) | |
Rated Output Power | 8000W |
Max. AC Output Power | 8800W |
Nominal Output Voltage | 220/230/240VAC |
Output Frequency | 50Hz / 60Hz |
Rated AC Output Current | 36.4A / 34.8A |
Max. AC Output Current | 40.0A / 38.3A |
Max. Continuous AC Passthrough | 50A |
Power Factor | 0.8 leading ~ 0.8 lagging |
Total Harmonic Distortion(THDi) | < 3% |
DC Current Injection | < 0.5 |
EFFICIENCY | |
Max. Efficiency (DC/AC) | 97.6% |
Euro Efficiency | 96.5% |
MPPT Efficiency | 99.0% |
BATTERY & CHARGER | |
Battery Type | Lead-acid or Lithium-ion |
Nominal DC Voltage | 40VDC – 60VDC |
Max. Charging Current | 190A |
Max. Discharging Current | 190A |
External Temperature Sensor | Yes |
Charging Curve | 3 Stages / Equalization |
Charging Strategy for Li-battery | Self-adaption to BMS |
PROTECTION | |
Anti-islanding Protection | Yes |
PV Input Reverse Polarity Protection | Yes |
Insulation Resistor Protection | Yes |
Residual Crrent Monitoring Unit | Yes |
Output Over Current Protection | Yes |
Output Short-circuit Protection | Yes |
Surge Protection | DC Type II / AC Type II |
Over Voltage Category | DC Type II / AC Type III |
INTERFACE | |
Communication Port | RS485/CAN, WiFi |
ENVIRONMENT | |
Operating Temperature | -40°C to 60 °C (>45 °C derating) |
Noise | < 50dB |
Protection Degree | IP65 |
Installation Style | Wall-mounted |
CERTIFICATION STANDARDS | |
Grid Regulation | IEC61727 / IEC62116, EN50549-1 |
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |