Hybrid Solar Inverter | 15KW | IP65 | Battery:125VDC - 600VDC | Max. PV:22500W | 3 Phase
Prostar PEI15K-3P high voltage 3 phase hybrid solar inverter 15kw offers flexible operation modes including On-Grid, Off-Grid, and UPS (Uninterruptible Power Supply). These modes can be programmed according to the user’s requirements, providing optimal performance in various scenarios.
When AC power is restoring after a power outage, the 3 phase hybrid solar inverter 15kw automatically restarts to ensure continuous operation and minimal disruption.
The hybrid solar inverter 15kw intelligently manages the flow of energy between the solar panels, batteries, and the grid. The system prioritizes self-consumption by ensuring that generated solar power is using on-site before any excess is fed back into the grid, maximizing savings and reducing the carbon footprint.
Users can easily set the priority for power supply from either the battery or the grid, providing flexibility in energy management based on individual needs.
Three-Phase Operation
Designed for three-phase grid connection, ensuring stable power supply and compatibility with most commercial and industrial electrical systems.
Mains and Generator Compatibility
The solar inverter is compatible with mains voltage and generator power, offering flexibility in power sourcing and backup solutions.
Multiple Protection Features
The hybrid solar inverter 15kw includes built-in protections against over-voltage, over-current, short circuits, and overheating, ensuring safe and reliable operation.
Advanced Load Adaptability
Capable of handling dynamic load demands with precision, the inverter adjusts to varying power requirements seamlessly.
Parallel Operation
The inverter can be paralleled up to 10 units for both on-grid and off-grid operations, allowing for scalable solutions in larger power installations.
Peak Shaving
Support peak shaving, allowing users to reduce energy costs by managing and minimizing peak demand charges.
100% Three-Phase Unbalanced Output
With the ability to handle a 100% unbalanced load across the three phases, this hybrid solar inverter ensures stable and efficient power distribution even under challenging conditions.
IP65 Protection
With its IP65-rated enclosure, it is resistant to dust, water, and other environmental factors, making it suitable for both indoor and outdoor installations.
Smart Monitoring & Control
Equipped with advanced monitoring features, the inverter allows for real-time tracking of energy production, consumption, and storage.
Connecting a Current Transformer (CT) sensor to an IP65 3-phase hybrid solar inverter is an important step for accurately measuring the current flowing through the system, which in turn allows for precise energy management and monitoring.
#1. CHINT Meter Wiring
#2. Eastron Meter Wiring
For the high battery voltage hybrid solar inverter in parallel operation, the lead-acid battery is not supported. Please use approved lithium battery.
Parallel operation requires precise voltage matching and synchronization between batteries. Lithium batteries are usually more consistent in their voltage output, making them better suited for this type of operation.
Residential Homes
Community Centers and Public Facilities
Industrial Facilities
Remote Areas and Off-Grid Locations
Telecommunication Towers
Model | PEI15K-3P |
PHASE | 3-phase in/ 3-phase out |
Max. PV INPUT POWER | 22500W |
Rated Output Power | 15KW |
Parallel Function | up to 2 units |
Dimension, D x W x H (mm) | 560x530x220 |
Net weight (kgs) | 32 |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 600VDC / 1000VDC |
Start-up Voltage | 125VDC |
MPPT Voltage Range | 180VDC~850VDC |
Full Power MPPT Voltage Range | 510VDC~850VDC |
Max. DC INPUT Current | 20A/20A |
Max. DC Short-circuit Current | 30A/30A |
No. of MPPT Trackers | 2 |
No. of String per MPPT Tracker | 2/2 |
GRID OUTPUT (AC) | |
Rated Output Power | 15KW |
Max. AC Output Power | 16.5KW |
Nominal Output Voltage | 380/400/415VAC |
Output Frequency | 50Hz / 60Hz |
Max. Apparent Power from Grid | 33KVA |
Max. Apparent Current from Grid | 38.1A |
Nominal AC Output Current | 21.7A |
Max. AC Output Current | 23.8A |
Power Factor | 1 (0.8 leading ~ 0.8 lagging) |
Total Harmonic Distortion(THDi) | < 3% |
AC Grid Tie | 3P+N+PE |
EPS OUTPUT (AC) | |
Rated Output Power | 15KW |
Max. Apparent Power | 16.5KVA |
Nominal Output Voltage | 380/400/415VAC |
Output Frequency | 50Hz / 60Hz |
Rated Output Current | 21.7A |
Max. Output Current | 23.8A |
Total Harmonic Distortion(THDu) | <2% |
EFFICIENCY | |
Max. Efficiency (DC/AC) | 98.1% |
Euro Efficiency | 97.5% |
MPPT Efficiency | 99.9% |
BATTERY & CHARGER | |
Battery Type | Lead-acid or Lithium-ion |
Nominal DC Voltage | 125VDC – 600VDC |
Working Voltage Range | 150VDC – 550VDC |
Max. Charging/Discharging Power | 16.5KW |
Rated Charging/Discharging Current | 40A |
Max. Charging/Discharging Current | 50A |
Min. Full Power Voltage @EPS | 385V |
Charging Curve | 3 Stages / Equalization |
Charging Strategy for Li-battery | Self-adaption to BMS |
PROTECTION | |
Protection | Island protection / PV reverse polarity protection / Battery reverse polarity protection / Insulation monitoring / Residual current monitoring / AC over current protection / AC over power protection / Back-up output short circuit protection / Short circuit protection / Insulation resistor detection |
INTERFACE | |
HMI | LCD, APP |
BMS | CAN |
EMS/Meter | RS485/RS485 |
WiFi | Yes |
ENVIRONMENT | |
Operating Temperature | -25°C to 60°C |
Relative Humidity | 0 ~95%(non-condensing) |
Altitude | 2000m (>2000 derating) |
Cooling | Natural |
Noise | < 35dB |
Protection Degree | IP65 |
Installation Style | Wall-mounted |
CERTIFICATION STANDARDS | |
Grid Regulation | Europe: EN 50549-1:2019/AC:2019, Poland:EN50549-1:2019/Rfg:2016/NC Rfg:2018/PTPiREE:2021, Germany:VDE-AR-N 4105:2018 /DIN VDE V 0124-100(VDE V 0124-100):2020, South Africa: NRS 097-2-1:2017 Edition 2.1, UK:G98/G99/1-6:2022, Spain: UNE217001:2020 /UNE217002:2020/NTS V2.1:2021-07, IEC61727:2004/IEC62116:2014/IEC61683:1999, Hungary:EN50549-1:2019/RFG:2016 Italy: CEI0-21 |
Safety EMC / Standard | IEC/EN 61000-6-1:2019, IEC/EN 61000-6-2:2019, IEC/EN 61000-6-3:2021, IEN/EN 61000-6-4:2019, IEC/EN 61000-3-2:2019/A1:2021, EN 61000-3-3:2013/A2:2021, IEC/EN 61000-3-11:2019, EN 61000-3-12:2011, IEC/EN62109-1:2010, IEC/EN62109-2:2011 |