Offline UPS | 1500VA/900W | 2*12V9AH VRLA Battery
Cheap small home offline standby smart ups 1500va 900w for computer is built-in 2 step boost & 1step buck stabilizer to maintain voltage stability, sensing abnormal voltage and regulating immediately.
Prostar computer ups power backup 500VA – 3000VA with battery inside passes the AC Mains Supply directly to the output load if the AC Mains Supply is present. Only in the case of power failure, it switches to inverter within few miliseconds to give power to load until mains supply returns.
Supplies power long enough for equipment to properly shut down when utility power fails. Helps prevent loss of data and minimizes the component stress caused by a hard shutdown.
Diverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage.
Computer UPS Internal Structure
Offline UPS built-in VRLA batteries
Offline UPS Rear Panel
Prostar offline UPS package
Model | 1500VA |
Capacity | 1.5KVA/900W |
Noise | Less than 40dB (Distance 1 Meter) |
Dimension(WxDxH mm) | 140x365x165 |
Weight(Kgs) | 11.90 |
INPUT | |
Voltage | 110Vac/120Vac/128Vac or 220Vac/230Vac/240Vac |
Voltage Range | 81Vac – 145Vac or 145Vac – 275Vac |
Frequency | 50Hz/60Hz (Auto)±10% |
OUTPUT | |
Voltage | 110Vac/120Vac/128Vac or 220Vac/230Vac/240Vac ± 10% |
Frequency | 50Hz/60Hz±1Hz |
Wave Form | Simulated sine wave |
Transfer Time | 4 – 6ms |
BATTERY | |
Type | VRLA Battery |
Battery Number | 2 Pieces |
Battery Capacity | 12V 9AH |
Charging Time(Standard) | 8 hours recover to 90% capacity |
INDICATORS | |
AC Mode | Green Lighting |
Battery Mode | Green flash every 10 seconds |
Fault | Red Lighting |
Low Battery | Green Lighting every second and red lighting |
ALARM | |
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding every second |
Fault | Continuously sounding |
SYSTEM | |
Protection | Discharge, Short Circuit, Low Battery, Temperature and Overload |
IP Protection | IP20 |
Display | LED(default) or LCD optional |
ENVIRONMENT | |
Operating Temperature | 0℃ to 40℃ |
Humidity | 0~95% (non-condensing) |
Altitude | <1000m (with increase of 100m,it will reduce output of 1%) max. 4000m |
MANAGEMENT | |
Communication Interface | Option for RS232, USB |
SNMP Optional | Power managemetn from SNMP manager and web browser |