GP5-12 small valve regulated sealed lead acid agm 12v 5ah battery uses a state of the art, heavy-duty, calcium-alloy grid that provides exceptional performance and service life in both float and cyclic applications.

The grid structure of the lead acid battery is made from a lead alloy. Pure lead is too soft and would not support itself, so small quantities of other metals are added to get the mechanical strength and improve electrical properties.

Valve regulated 12v 5ah battery is an Absorbent Glass Mat (AGM) technology with a valve regulated design, that can be used in enclosed and indoor environments without leaking or maintenance, providing a superior performance for thousands of models.

12v 5ah Battery Benefits

Battery Applications

TECHNICAL SPECIFICATIONS

Nominal Voltage 12V
 Nominal Capacity (20 hour rate) 5Ah
Capacity

25℃(77°F)

10 hour rate (0.48A) 4.8Ah
5 hour rate (0.89A) 4.45Ah
1 hour rate (3.3A) 3.3Ah
Internal Resistance Full Charged Battery 25℃ ≤30mΩ
Capacity affected by Temperature

(10 hour )

40℃ (104°F) 102%
25℃ (77°F) 100%
0℃ (32°F) 85%
-15℃ (5°F) 65%
Self-Discharge

25℃(77°F) Capacity

after 3 month storage 90%
after 6 month storage 80%
after 12 month storage 62%
Charge (Constant Voltage) 25℃(77°F) Float Initial Charging Current Less than 1.5A

Voltage13.6-13.8V

Cycle Initial Charging Current Less than 1.5A

Voltage 14.4-15.0V

DIMENSIONS & WEIGHT

Battery Dimensions Length 90mm
Width 70mm
Height 101mm
Total Height 107mm
Box Dimensions Length 389mm
Width 200mm
Height 147mm
Quantity Per Box 10 pcs per box
Net weight Per Cell 1.55 kg±50g
Net weight Per Box 15.5kg
Gross Weight 15.9kg

Discharge Constant Current per Cell (Amperes at 77°F25°C)

F.V/Time 5min 10min 15min 30min 45min 1h 2h 3h 5h 8h 10h 20h
16.50 16.50 11.00 8.28 5.50 3.85 3.30 2.06 1.41 0.94 0.63 0.52 0.28
16.20 16.20 10.80 8.13 5.40 3.78 3.24 2.03 1.39 0.93 0.62 0.51 0.27
15.90 15.90 10.60 7.98 5.30 3.71 3.18 1.99 1.36 0.91 0.61 0.50 0.27
15.60 15.60 10.40 7.83 5.20 3.64 3.12 1.95 1.34 0.89 0.60 0.49 0.26
15.00 15.00 10.00 7.52 5.00 3.50 3.00 1.88 1.28 0.86 0.58 0.48 0.25

Discharge Constant Power per Cell (Watts at 77°F 25°C)

F.V/Time 5min 10min 15min 30min 45min 1h 2h 3h 5h 8h 10h 20h
1.60V 31.76 21.18 15.93 10.59 7.41 6.35 3.97 2.72 1.81 1.22 1.01 0.53
1.65V 31.19 20.79 15.64 10.40 7.28 6.24 3.90 2.67 1.78 1.20 0.99 0.52
1.70V 30.61 20.41 15.35 10.20 7.14 6.12 3.83 2.62 1.75 1.18 0.97 0.51
1.75V 30.03 20.02 15.06 10.01 7.01 6.01 3.75 2.57 1.72 1.15 0.95 0.50
1.80V 28.88 19.25 14.48 9.63 6.74 5.78 3.61 2.47 1.65 1.11 0.92 0.48