Guangdong Prostar New Energy Technology Co., Ltd.

GP9-12 small sealed lead acid sla agm 12v 9ah battery price for ups

agm 12v 9ah battery price for ups

GP9-12 small sealed lead acid sla agm 12v 9ah battery price for ups has been specifically designed for general purpose and standby applications. The 12v 9ah battery offers excellent performance in a wide range of applications including security and fire systems, medical devices, emergency lighting and UPS systems.

The grid structure of the lead acid battery is made from a lead alloy. Pure lead is too soft and would not support itself, so small quantities of other metals are added to get the mechanical strength and improve electrical properties.

AGM lead acid 12v 9ah battery is an Absorbent Glass Mat (AGM) technology with a valve regulated design, that can be used in enclosed and indoor environments without leaking or maintenance, providing a superior performance for thousands of models.

12v 9ah Battery Benefits

Battery Applications

TECHNICAL SPECIFICATIONS

Nominal Voltage 12V
 Nominal Capacity (20 hour rate) 9.0Ah
Capacity

25℃(77°F)

10 hour rate (0.83A) 8.3Ah
5 hour rate (1.51A) 7.55Ah
1 hour rate (5.67A) 5.67Ah
Internal Resistance Full Charged Battery 25℃ ≤20mΩ
Capacity affected by Temperature

(10 hour )

40℃ (104°F) 102%
25℃ (77°F) 100%
0℃ (32°F) 85%
-15℃ (5°F) 65%
Self-Discharge

25℃(77°F) Capacity

after 3 month storage 90%
after 6 month storage 80%
after 12 month storage 62%
Charge (Constant Voltage) 25℃(77°F) Float Initial Charging Current Less than 2.7A

Voltage 13.6-13.8V

Cycle Initial Charging Current Less than 2.7A

Voltage 14.4-15.0V

DIMENSIONS & WEIGHT

Battery Dimensions Length 151mm
Width 65mm
Height 95mm
Total Height 101mm
Box Dimensions Length 364mm
Width 165mm
Height 141mm
Quantity Per Box 5 pcs per box
Net weight Per Cell 2.5 kg±100g
Net weight Per Box 12kg
Gross Weight 12.5kg

Discharge Constant Current per Cell (Amperes at 77°F25°C)

F.V/Time 5min 10min 15min 30min 45min 1h 2h 3h 5h 8h 10h 20h
1.60V 29.5 23.3 17.1 9.76 6.95 5.67 3.51 2.40 1.60 1.08 0.89 0.47
1.65V 28.7 22.7 16.7 9.50 6.76 5.47 3.44 2.36 1.57 1.06 0.87 0.46
1.70V 27.9 22.1 16.2 9.24 6.58 5.28 3.38 2.32 1.54 1.04 0.86 0.45
1.75V 27.1 21.4 15.8 8.97 6.39 5.08 3.32 2.27 1.51 1.02 0.84 0.45
1.80V 26.4 20.8 15.3 8.71 6.21 4.89 3.19 2.18 1.46 0.98 0.83 0.45

Discharge Constant Power per Cell (Watts at 77°F 25°C)

F.V/Time 5min 10min 15min 30min 45min 1h 2h 3h 5h 8h 10h 20h
1.60V 56.8 44.9 33.0 18.78 13.38 10.91 6.75 4.63 3.08 2.07 1.71 0.90
1.65V 55.3 43.7 32.1 18.28 13.02 10.54 6.63 4.54 3.03 2.04 1.68 0.88
1.70V 53.8 42.5 31.2 17.78 12.66 10.16 6.50 4.46 2.97 2.00 1.65 0.87
1.75V 52.2 41.3 30.3 17.27 12.30 9.78 6.38 4.37 2.92 1.96 1.62 0.85
1.80V 50.7 40.1 29.5 16.77 11.94 9.41 6.14 4.21 2.80 1.88 1.56 0.82