3 phase UPS | 160KVA/128KW | 3 Phases 4 Wires | 380Vac/400Vac/415Vac | 480Vdc
Prostar GT160K 3 phase transformer based industrial igbt 160kva ups system offers technology that increases performance and reliability. Online technology fully isolates and protects against all power quality disturbances. The upstream harmonics management allows a generator friendly installation and flexible configurations for even the most demanding designs.
3 phase transformer based industrial 160kva ups system offers features such as paralleling capability for N+1 or N+X redundancy, full front access, included start up for ease of serviceability, user friendly graphical display with multiple language options, and SNMP with network based power management options.
Modern Medical systems, especially hospital facilities, rely heavily on the continuous, uninterrupted power supply(UPS) to run equipment that saves lives and protects vital electronic data. Even a brief interruption of electricity can be harmful to patients who are undergoing surgery or machine diagnosis.
Hospitals are the core of community response in an emergency. In the event of a power outage, a reliable UPS system can protect patients, staff, and data alike to maintain a hospital’s high efficiency and critical functions running without interruption.
Prostar UPS for hospital and medical system providers adhere to the most stringent safety standards. By ensuring zero downtime for the entire electrical system, Prostar UPS helps the heart of hospital beating all the time.
Prostar uninterruptable power supply is industry-leading efficiency, availability, and performance for small, medium, large data centers and mission critical environments.
3 Phase Online UPS is designed to meet the toughest product customization requirements for specific mechanical protection degree. A 3:1 crest factor safely supports a variety of loads, even those with wildly fluctuating power demands.
1) DSP digital control technology
Core system uses the world’s most advanced all-digital DSP control technology, which can effectively guarantee the UPS’ core system accurate, and fast running.
Online UPS DSP Control Module
2) Advanced IGBT inverter technology
Combined high-reliable and high-efficiency IGBT inverter technology with high-frequency Pulse Width Modulation technology (PWM).
It could reduce noise and power loss, to ensure users can load in a variety of working situations and obtain high-quality voltage output and maximum cost-effectiveness, but also make input efficiency more than 95%.
InFineon IGBT Module
3) Pure-online double conversion technology
Reliable and stable, after filtered and regulated, the output sine wave from pure-online double conversion technology, not only has the atmospheric disturbance suppression filter, but also with the standard output isolation transformers, static bypass, maintenance bypass, make this product with higher ability to engage in short circuit current. And it can be applied to the worst working environment.
Online Double Conversion Technology
4) Perfect Protection
Perfectly system protection functions: It has AC over-voltage, under-voltage, output over-voltage, under-voltage, output overload, short circuit protection, inverter, rectifier over-temperature protection, voltage under-voltage warning, battery over charging protection and other protections in one to ensure the system to operate stably and reliably.
5) Powerful Redundant Parallel Connection Function
Durable and reliable design of industrial-type modular structure, combined with full digital DSP control technology core system, make this product not only can be used for N +1 / N + X redundancy and the ability of enlarge the capacity, but also permit different power and different times of the UPS could be in parallel. It greatly reduced the user’s pre-and post-purchasing costs, and increased capacity costs, but also expanded upper spaces of increasing capacity.
UPS Redundant Parallel Connection
6) Powerful communication system
The standard equipped with RS232 interface, dry contact relays, emergency switching device EPO input interface.
7) Low-power dissipation but high-efficiency
To achieve more than 98% of ultra-high efficiency under ECO economic model, which can effectively bring down the amount of electricity, and effective in accordance with the requirements of energy-saving target of the country.
8) Prediction warning system
LCD panel automatic detection function and timely warning in advance, with the boot self-diagnosis function. It could avoid the hidden danger in time due to UPS’ failure, which caused risks. Also it could automatically alarm by setting the battery discharge to standby time is less than a set value.
9) Humanized panel display
Humanized panel settings, the users can set system parameters, date, output voltage, battery capacity, alarm function, light-load shutdown, system boot time, MODEM settings, such as orders, also it can be up to 120 abnormal failure information for users to query.
10) Super-strong environment adaptability
This product has superior environmental adaptability, wide AC input range, greatly reduces the frequency of battery using, and effectively extends the battery life.
11) Powerful Overload Ability
Using the pure-online double conversion technology, with the output isolation transformers, static bypass, and maintenance bypass.
Inverter Overload Ability reached 110% / 125% / 150% overloading time can last for 300min/10min/1min.
Bypass Overload Ability reached 150% / 170% / 250% overloading time can last for 60min/10min/1min.
Model | GT160K |
Capacity | 160KVA/128KW |
UPS Efficiency | >95% |
Noise | 48dB~54dB(Distance 1 Meter) |
Dimension(WxDxH mm) | 1070x750x1400 |
Weight(Kgs) | 940 |
INPUT | |
Voltage | 3 Phases 4 Wires, 380Vac/400Vac/415Vac ± 25% |
Frequency | 50Hz/60Hz±5% (Automaticly) |
Power Factor | ≥0.95 |
OUTPUT | |
Voltage | 3 Phases 4 Wires, 380Vac/400Vac/415Vac ± 1% |
Frequency | 50Hz/60Hz±0.05%(By Battery) |
Harmonic Distortion | Linear load<3%, Non-linear load<5% |
Imbalance Voltage | Balance load≤1%, Imbalance load≤3% |
Phase Shif Angle | Balance load≤1°, Imbalance load≤2° |
Transient Response | Output at 0~50%~100% ≤5%, response ≤ 10ms |
Overload Capacity | 110%≥300Min, 125%≥10Min, 150%≥1Min |
Crest Factor | 3:1 |
Wave Form | Pure sine wave |
Transfer Time | 0ms |
BATTERY | |
Type | Support VRLA Battery |
D.C. Voltage | 480Vdc |
Max. Charging Current | 0.2AxC10 |
Charging Time(Standard) | 12hours |
SYSTEM | |
Protection | Input over-voltage, under-voltage; output overload, shortcircuit; Inverter over-temperature; Battery under-voltage,over-voltage |
IP Protection | IP20 |
Parallel Mode | N+1,N+X,can be in parallel with differenct power capacity |
Software Interface | Windows9x,2000,NT,ME,XP,Linux,Novell,Macosx,NT4.0 |
Meantime Between Failures | 300,000Hours |
ENVIRONMENT | |
Operating Temperature | 0℃ to 40℃ |
Humidity | 0~95% (non-condensing) |
Altitude | <1000m (with increase of 100m,it will reduce output of 1%) max. 4000m |
Storage Temperature | -15℃ to 50℃ |
MANAGEMENT | |
Communication Interface | RS232/RS485 |
Remote Signaling | Dry contact (battery low,battery discharging,bapass/fault),EPO |
Remote Control | EPO and bypass |
SNMP | Power managemetn from SNMP manager and web browser |
Optional | Dustproof & dampproof, Isolating inverter transformer, lightning surge absorption, static switches, manual maintainence switch |