MPS20KLV hot-swapped modular ups power module 20kW 208V 220V

3 Phase Modular UPS Power Modular | 20KVA / 20KW | 3 Phases 4 Wires | 208V/220V | +/-120Vdc | Pure Sine Wave

SKU: MPS20KLV Category:

Prostar MPS20KLV hot-swapped modular ups power module 20kW 208V 220V can provide uninterrupted, high-performance power solutions for critical applications.

The hot-swappable Power Modules allow quick maintenance and expansion. A latch located on the front of each module fixes and locks the module in its assigned slot. Each Power Module has an LED indicator to show its operation status.

 

Delivers a robust 20kW output in a compact form factor, optimizing space usage and reducing footprint. Each 20kW power module can be hot-swapped, allowing for seamless maintenance and scalability without interrupting the power supply.

Equipped with adaptive load management, the power module 20kVA 20kW can adjust to varying power demands, ensuring consistent performance under all conditions.

MPS20KLV hot-swapped modular ups power module 20kW 208V 220V

 

Power Module 20KW Features

  • Easy hot swap design
  • Output factor is 1 (kVA = kW)
  • Power module can be scalable system
  • Flexible modular design
  • No downtime system
  • Automatic restart of loads after UPS shutdown
  • Input Power Factor Correction
  • Predictive failure notification
  • Intelligent battery management
  • N+1 or N+x redundant parallel
  • Save time with easy and convenient remote accessibility
  • Repeatable and standardised assets to meet different configuration and architectural requirements

Power Module Details

Modular UPS 30 kVA Power Modular Rear Panel

Power Module Rear Panel Information

Modular UPS Power Modular Switch Setting

Key Benefits of the 20kW UPS Power Module

Reliable Power Protection

Designed to provide continuous power, this UPS module ensures that critical systems remain operational during outages or fluctuations, protecting sensitive equipment from power surges, dips, and blackouts.

Scalability and Flexibility

With a modular design, you can easily expand or upgrade the system by adding additional 20kW modules. This allows businesses to grow their power capacity incrementally, optimizing capital investments and future-proofing infrastructure.

Cost-Efficient Operations

High energy efficiency (up to 96%) reduces power losses and cuts down on electricity costs, making it an eco-friendly and budget-conscious choice. The advanced battery management also minimizes replacement costs by extending battery life.

Simplified Maintenance and Downtime Reduction

Hot-swappable modules mean maintenance can be done without shutting down the system, reducing downtime and ensuring seamless power continuity even during repairs or upgrades.

Enhanced Monitoring and Control

Remote monitoring and control allow users to proactively manage power usage and respond quickly to potential issues, which can minimize downtime and improve efficiency. This feature is especially valuable for facilities with high operational demands and limited on-site technical staff.

 

The Articles You may Like

 

Model MPS20KLV
Capacity 20kVA / 20KW
Phase 3-phase in / 3-phase out
Battery Voltage +/- 120V
Size, D X W X H (mm) 736.5x490x133(3U)
Cabinet Net Weight (Kgs) 34.5
INPUT
Input Voltage 208VAC/220VAC(3Ph+N)
Voltage Range 182V~253V at 90%~100% Load; 156~253V  at 63%~90% Load; 121~253Vfor <63% Load
Nominal Frequency 50/60Hz(Auto Sensing)
Frequency Range 40Hz~70Hz
Power Factor >0.99 @ 100% Load, >0.98 @ 50% Load
Harmonic Distortion (THDi) < 3% @ 100% Load
OUTPUT
Nominal Voltage 208VAC/220VAC (3Ph+N)
Voltage Regulation(Steady state) ≤±1%Typical(balanced Load);≤±2% Typical (unbalanced Load)
Nominal Frequency 50/60Hz
Frequency Range(Synchronized) 46Hz~54Hz or 56Hz~64Hz
Power Factor 1 (kVA=kW)
Overload Capability 1 hour for 110%, 10 mins for 120%, 1 min for 150%, 200ms for >150%
Harmonic Distortion ≤2% THD(Linear Load); ≤4% THD( Non-linear Load )
EFFICIENCY
Online Mode Up to 92.5% at over 50% load
BATTERY/CHARGER
Nominal Voltage +/- 120V (12V x 20Pcs)
Float Charging Voltage 2.3V/Cell
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current 8A (User adjustable)
STANDARDS
Safety UL1778, CSA C22.2 No. 107.3-05
EMC FCC Part 15, Subpart B Class A
ENVIRONMENT
Operation Temperature 0~40°C
Relative Humidity 0~95% Non-condensing
Altitude <1000m for Nominal power
IP Class IP20