Prostar MPS90K-15U 90kva uninterruptible power supply data center supports multiple operational modes such as Eco Mode, Double Conversion Mode, and Battery Mode. These modes optimize power usage based on the current load and grid conditions, achieving up to 96% efficiency in double conversion mode and up to 99% in Eco Mode.
Advanced load segmentation allows critical loads to remain powered longer during extended power outages, prioritizing the most essential equipment.
With an intuitive user interface, the uninterruptible power supply data center ups simplifies operation and maintenance tasks, allowing IT personnel to manage the system effectively.
Modular UPS 90kVA Features
Compact Design
Despite its robust power output, the modular UPS boasts a compact footprint that is ideal for space-constrained environments. You can configure it in a rack-mount or stand-alone configuration, making it adaptable to various installation requirements.
High Efficiency Online Double Conversion Technology
By utilizing online double conversion technology, the uninterruptible power supply data center achieves high power efficiency while delivering a pure sine wave output, ensuring stable power for sensitive equipment.
Output Power Factor 1
This system provides a unity power factor (PF 1.0), maximizing power output efficiency and effectively supporting all connected loads.
Hot Swappable Modules
The UPS uninterruptible power supply data center is built with hot-swappable modules that allow for maintenance or replacement without shutting down the power supply to connected systems. This feature minimizes downtime and ensures business continuity.
Remote Management
Equipped with advanced remote monitoring and management capabilities, the UPS can be controlled and monitored from anywhere, providing real-time information on system status and performance.
Audible Alarms and LED Indicators
Clear audible alarms and visual indicators provide immediate feedback about the UPS’s status and any potential issues, alerting operators to take corrective actions promptly.
Adjustable Battery Numbers
The flexibility to adjust the number of batteries allows for custom power configurations, optimizing battery usage and storage.
1+1 Cabinets Parallel Support
For enhanced redundancy and capacity expansion, the modular ups power supports parallel operation in a 1+1 cabinet configuration, providing scalable power solutions for growing infrastructure.
Uninterruptible Power Supply Data Center Introduction
In the front of the UPS, there are control interface (LCD Panel), communication slots, communication ports and 3 Power Module slots.
All wiring terminal blocks are allocated in the back of cabinet. The side panels are locked by screws. The casters at the bottom of the UPS cabinet can be used to move over for short distances. There are two leveling feet to fix and stabilize the UPS cabinet on the ground.
Modular UPS Wiring Terminal Blocks
When discussing the wiring terminal blocks of a modular UPS like the MPS90K-15U, it’s important to understand how these components facilitate the connection and management of power distribution. The terminal blocks serve as the points where wires are connected to the UPS for both input and output power, as well as for optional auxiliary functions such as battery connections and external monitoring devices.
When connecting wires to the terminal blocks, ensure that:
- The correct wire gauge is used for the application.
- Connections are secure and tight to prevent loose contacts that could lead to overheating or poor conductivity.
- All connections comply with the UPS manufacturer’s specifications and local electrical codes.
- Proper labeling is applied to each wire for easy identification and future maintenance.
External Battery Connection
External batteries can extend the runtime of the UPS significantly, depending on the capacity and number of batteries installed.
UPS Installation Drawing
Modular UPS Power Module Installation
The 30 kVA Power Module has independent hardware and controllability, able to operate and coordinate with other modules within the system. See details:
MPS30K 3 phase modular ups system hot swappable power module 30kw
Warning: The power modules installed in the same cabinet must be at the same rating.
One. Access the Modular Bay
- Locate the Modular Bay: Identify the empty slot or bay within the UPS chassis and install the new power module there.
- Remove Obstructions: Clear any obstructions that might interfere with the installation, such as covers or panels.
Two. Prepare the Power Module
- Inspect the Module: Check that the power module is undamaging and meets the specifications required for your UPS system.
- Prepare Connectors: If the module comes with pre-wired connectors, ensure they are ready to plug into the UPS.
Three. Install the Power Module
- Adjust the DIP switch positions to set the different Module Address.
- Place the ready switch at the front panel of the module to the un-lock position.
- Align the power module with the slot, ensuring that it fits properly.
- Once aligned, gently push the module into place until it clicks or locks securely. Fasten any screws or clips that hold the module in position.
- Move the ready switch to the lock position.
Four. Connect the Cables
- Connect Internal Wires: Connect any internal wires or connectors from the power module to the UPS chassis. Ensure all connections are tight and secure.
- Battery Connections: If the module has battery connections, connect these according to the manufacturer’s guidelines. Pay close attention to polarity (positive and negative connections).
- Signal and Control Wires: Connect any signal or control wires that might require for the proper functioning of the module.
Five. Finalize Installation
- Check Connections: Double-check all connections to ensure they are secure and correctly made.
- Reinstall Panels: Replace any removed panels or covers, align them properly, and secure them.
- Test the Installation: Power on the UPS and verify that the new power module is recognized and functioning correctly. Monitor the UPS through its display or management software to confirm proper operation.
UPS Uninterruptible Power Supply Data Center Applications
Data Centers and IT Infrastructure
Ensures consistent power for servers, storage systems, and networking equipment, critical for uninterrupted operations. The modular design allows for easy scaling as the data center grows, and the high efficiency reduces operational costs.
Telecommunications
Provides stable power to telecom equipment, supporting high loads and preventing downtime in network infrastructure. The system’s adjustability and high output power factor make it an optimal choice for large-scale telecom facilities.
Financial and Banking Institutions
Powers IT and security systems critical for banking transactions and data security, ensuring a consistent power supply during outages or fluctuations.
Transportation Hubs
Airports, railway stations, and other transportation hubs depend on the UPS to keep critical systems such as ticketing, baggage handling, and security operations running smoothly.
Government and Educational Institutions
Supports data centers, research labs, and administrative facilities with scalable, resilient power management. The 1+1 parallel cabinet configuration ensures redundancy and fault tolerance for vital operations.
The Articles You may Like
- What Can You Run Off a 3000W Inverter
- How Long will 48V 100AH Lithium Battery Last?
- Uninterruptible power supply – Wikipedia
- A Step-by-Step Guide to UPS Sizing Based on Motor Load Calculation
- Understanding How Scalable Modular UPS Systems Work
- Why 3 Phase Solar Power Inverter is Essential for Large-Scale Solar Projects
- Can Off Grid Solar Inverter Charge Controller Run without Battery