• PER1102 best 220v rack mount pure sine wave 2000va ups power source
  • PER1102 best 220v rack mount pure sine wave 2000va ups power source

PER1102 best 220v rack mount pure sine wave 2000va ups power source

Rack Mount UPS | 2kVA/2kW | PF 1.0 | 72Vdc | 208V/220V/230V/240V | Without battery inside

SKU: PER1102 Category:

Prostar PER1102 best 220v rack mount pure sine wave 2000va ups power source provides management of the UPS via a smart slot.

PER1102 rack mount 2000va ups adopts advanced technology to enhance UPS operating efficiency, reduce heat generation, consume less power and save more energy costs.

The ECO and frequency inverter operation modes highlight the requirements for a modern versatile UPS.

The PF1.0 rack mount ups provides Pure Sine Wave power output for sensitive equipment that requires smoother and cleaner input source.

Prostar Rack Mount Online UPS 1KVA - 3KVA

2U rack mount 2000va UPS avoids costly power problems by keeping your IT equipment and data protected and available.

Rack Mount 2000VA UPS Features

  • True double conversion
  • Microprocessor control optimizes reliability
  • DSP technology guarantees high performance
  • Input power factor correction
  • Output power factor 1
  • Extremely wide input voltage window of 110 VAC to 300 VAC
  • High efficiency up to 95.5%
  • 50Hz/60Hz frequency converter mode
  • ECO mode for energy saving
  • Emergency power off (EPO) function
  • Graphic LCD display with interactive multilingual user interface
  • Adjustable battery numbers
  • Adjustable charging current via LCD panel
  • Adjustable charging mode with two stages or three stages
  • Charger capacity expansion to 12A for long-run models
  • Programmable output voltage
  • Cold start by battery without grid input
  • Smart battery charging technology for maximum durability of the battery
  • Generator compatible
  • Extension slot for SNMP

Rack Mount Online UPS Rear Panel

Rack Mount UPS 2KVA 2KW Rear Details

 

1.Smart slot                                                                               10.Maintenance bypass switch (option)
2.RS-232 port                                                                           11.Cooling fan
3.Output receptacles                                                               12.AC Input terminal
4.Ground terminal                                                                   13.AC Output terminal
5.External battery connector                                                 14.AC Input/Output terminal
6.Emergency power off connector (option)                        15.Battery pack output circuit breaker
7.USB port                                                                                 16.Battery bank
8.Input circuit breaker                                                            17.Rack mount hole
9.AC Input socket                                                                     18.Parallel operation port (option)

2U Rack Mount UPS Highligh

Prostar PER Rack Mount Online UPS Efficiency

Prostar Rack Mount Online UPS Adjustable Battery Numbers

Prostar Rack Mount Online UPS Charging Current up to 12A

Prostar Rack Mount Online UPS Multiple Protection

Single Phase 2000VA UPS Details

PER1102 best 220v rack mount pure sine wave 2000va ups power source

PER1102 best 220v rack mount pure sine wave 2000va ups power source

PER1102 best 220v rack mount pure sine wave 2000va ups power source

 UPS Power Supply FAQ

  1. What is a rack mounted UPS?

    A rack mount UPS supplies uninterrupted power to the connected devices in the event of a power failure, thereby preventing failure of equipment and loss of data. A rack mount UPS is ideal for workplaces with networking and server applications.

  2. What is a UPS Tower?

    An uninterruptible power supply (UPS) is an electrical setup that provides power backup when the main power source fails. It is commonly used to protect hardware such as computers, telecommunication equipment, and other sensitive electronics.

  3. What is the difference between a PDU and a UPS?

    PDUs merely distribute power. They do not generate it. UPSs are essentially backup batteries in the server rack. They provide backup power in the event of an outage and complete protection against power quality problems.

The Articles You may Like

MODEL PER1102
CAPACITY 2000VA / 2000W
Battery Voltage 48VDC/72VDC(default)
Size, D X W X H (mm) 440x420x88
Net Weight (kgs) 6.5
INPUT
Nominal Voltage 208/220/230/240VAC
Input Voltage Range 110-300VAC
Frequency Range 50Hz:44Hz~56Hz or 60Hz:54Hz~66Hz
Phase Single Phase, L+N+PE
Power Factor ≧ 0.99 @ nominal voltage (input voltage)
Harmonic Distortion ≤4% (Linear Load), ≤5% (Non-linear Load)
OUTPUT
Output voltage 208/220/230/240VAC
AC Voltage Regulation ± 1% (Batt. Mode)
Frequency Range(Line Mode) Synchronized range
Frequency Range (Batt. Mode) 50Hz ± 0.25Hz or 60Hz ± 0.3Hz
Overload Capacity 30mins @102%-110% load
10mins @110%-130% load
30sec @130%-150% load
200ms @>150% load
Current Crest Ratio 3:1
Harmonic Distortion ≦3% THD (Linear Load);≦6% THD (Non-linear Load)
Transfer Time AC Mode to Battery Mode 0ms
Inverter to Bypass 4ms
Waveform (Batt. Mode) Pure Sine Wave
EFFICIENCY
AC Mode 95.5%
Battery Mode 91.5%
BATTERY
Battery Type Depending on applications
Battery Numbers 6 PCS
Charging Current 5A(Default),1A-12A adjustable
Charging Voltage 81VDC ± 1%
Charging Mode 2-stage(CC/ Floating) or 3-stage (CC/CV/Floating)
INDICATORS
LCD Panel Load level, Battery level, AC mode, Battery mode, Bypass mode,and Fault conditions
ENVIRONMENT
Ambient temperature 0- 40°C
Operation Humidity 5%-95% (non-condensing)
Storage temperature -15~60℃ (no battery inside)
Altitude <1000m ( the height above 1000m should be reduced to a maximum of 4000m.)
Noise Level Less than 50dBA @ 1 Meter
COMMUNICATION
Communication Interface Standard: RS232, USB; Option: Dry contact, EPO
Smart Slot Optional SNMP Card