Rack Mount UPS | 6kVA/6kW | PF 1.0 | 192Vdc | 208V/220V/230V/240V | Without battery inside

SKU: PER1106 Category:

Prostar PER1106 single phase server rack mount double conversion ups 6kva warns when a battery is not available to provide backup power.

PER1106 rack mount double conversion ups 6kva is low operating and maintenance costs with proven reliability and intelligent battery management.

The UPS’s output power factor is 1.0, which means that more critical devices with higher amount of total watts can be powered by the UPS, utilizing more loads efficiently.

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Prostar Rack Mount Online UPS 6KVA - 10KVA

Double Conversion UPS 6KVA Features

  • True double conversion
  • Microprocessor control optimizes reliability
  • DSP technology guarantees high performance
  • Input power factor correction
  • Output power factor 1
  • Extremely wide input voltage window of 110 VAC to 300 VAC
  • High efficiency up to 95.5%
  • 50Hz/60Hz frequency converter mode
  • ECO mode for energy saving
  • Emergency power off (EPO) function
  • Graphic LCD display with interactive multilingual user interface
  • Adjustable battery numbers
  • Adjustable charging current via LCD panel
  • Adjustable charging mode with two stages or three stages
  • Charger capacity expansion to 12A for long-run models
  • Programmable output voltage
  • Cold start by battery without grid input
  • Smart battery charging technology for maximum durability of the battery
  • Generator compatible
  • Extension slot for SNMP
  • Optional N+X parallel redundancy and performance increase

Rack Mount Online UPS Rear Panel

Rack Mount UPS 6KVA 6KW Rear Details

1.Smart slot                                                                               10.Maintenance bypass switch (option)
2.RS-232 port                                                                           11.Cooling fan
3.Output receptacles                                                               12.AC Input terminal
4.Ground terminal                                                                   13.AC Output terminal
5.External battery connector                                                 14.AC Input/Output terminal
6.Emergency power off connector (option)                                15.Battery pack output circuit breaker
7.USB port                                                                               16.Battery bank
8.Input circuit breaker                                                            17.Rack mount hole
9.AC Input socket                                                                     18.Parallel operation port (option)

Rack Mount Online UPS Highligh

Prostar PER Rack Mount Online UPS Efficiency

Prostar Rack Mount Online UPS Adjustable Battery Numbers

Prostar Rack Mount Online UPS Charging Current up to 12A

Prostar Rack Mount Online UPS EPO

Rack Mount Double Conversion UPS 6KVA Details

PER1106 single phase server rack mount double conversion ups 6kva

PER1106 single phase server rack mount double conversion ups 6kva

PER1106 single phase server rack mount double conversion ups 6kva

 UPS Power Supply FAQ

  1. Can a UPS power a TV?

    You can power a TV with an Uninterrupted Power Supply (UPS), and depending on the size (and cost) of the power supply it may keep the TV going for anywhere from 15 minutes to 2 hours. It’s smart to use a UPS for your TV (or other expensive electrical equipment) as cost-effective insurance.

  2. What is a UPS Tower?

    An uninterruptible power supply (UPS) is an electrical setup that provides power backup when the main power source fails. It is commonly used to protect hardware such as computers, telecommunication equipment, and other sensitive electronics.

  3. What is the difference between a PDU and a UPS?

    PDUs merely distribute power. They do not generate it. UPSs are essentially backup batteries in the server rack. They provide backup power in the event of an outage and complete protection against power quality problems.

The Articles You may Like

MODEL PER1106
CAPACITY 6000VA / 6000W
Battery Voltage 192VDC(default) / 240VDC
Size, D X W X H (mm) 440X420X88
Net Weight (kgs) 10
INPUT
Nominal Voltage 208/220/230/240VAC
Input Voltage Range 110-300VAC
Frequency Range 50Hz:44Hz~56Hz or 60Hz:54Hz~66Hz
Phase Single Phase, L+N+PE
Power Factor ≧ 0.99 @ nominal voltage (input voltage)
Harmonic Distortion ≤4% (Linear Load), ≤5% (Non-linear Load)
OUTPUT
Output voltage 208/220/230/240VAC
AC Voltage Regulation ± 1% (Batt. Mode)
Frequency Range(Line Mode) Synchronized range
Frequency Range (Batt. Mode) 50Hz ± 0.25Hz or 60Hz ± 0.3Hz
Overload Capacity 30mins @102%-110% load
10mins @110%-130% load
30sec @130%-150% load
200ms @>150% load
Current Crest Ratio 3:1
Harmonic Distortion ≦3% THD (Linear Load);≦6% THD (Non-linear Load)
Transfer Time AC Mode to Battery Mode 0ms
Inverter to Bypass 0ms
Waveform (Batt. Mode) Pure Sine Wave
EFFICIENCY
AC Mode 95.5%
Battery Mode 95.3%
BATTERY
Battery Type Depending on applications
Battery Numbers 16 PCS
Charging Current 5A(Default),1A-12A adjustable
Charging Voltage 216VDC ± 1%
Charging Mode 2-stage(CC/ Floating) or 3-stage (CC/CV/Floating)
INDICATORS
LCD Panel Load level, Battery level, AC mode, Battery mode, Bypass mode,and Fault conditions
ENVIRONMENT
Ambient temperature 0- 40°C
Operation Humidity 5%-95% (non-condensing)
Storage temperature -15~60℃ (no battery inside)
Altitude <1000m ( the height above 1000m should be reduced to a maximum of 4000m.)
Noise Level Less than 50dBA @ 1 Meter
COMMUNICATION
Communication Interface Standard: RS232, USB; Option: Dry contact, EPO