Prostar PER1110 single phase 10kva rack mount ups power supply for computer provides temporary battery power when the utility power is out.
PER1110 rack mount 10kva ups power supply protects connected loads from surges, spikes, lightning, and other power disturbances.
The UPS’s output power factor is 1.0, which means that more critical devices with higher amount of total watts can be powered by the UPS, utilizing more loads efficiently.
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Rack Mount 10KVA UPS Power Supply Features
- True double conversion
- Microprocessor control optimizes reliability
- DSP technology guarantees high performance
- Input power factor correction
- Output power factor 1
- Extremely wide input voltage window of 110 VAC to 300 VAC
- High efficiency up to 95.5%
- 50Hz/60Hz frequency converter mode
- ECO mode for energy saving
- Emergency power off (EPO) function
- Graphic LCD display with interactive multilingual user interface
- Adjustable battery numbers
- Adjustable charging current via LCD panel
- Adjustable charging mode with two stages or three stages
- Charger capacity expansion to 12A for long-run models
- Programmable output voltage
- Cold start by battery without grid input
- Smart battery charging technology for maximum durability of the battery
- Generator compatible
- Extension slot for SNMP
- Optional N+X parallel redundancy and performance increase
Rack Mount Online UPS Rear Panel
1.Smart slot 10.Maintenance bypass switch (option)
2.RS-232 port 11.Cooling fan
3.Output receptacles 12.AC Input terminal
4.Ground terminal 13.AC Output terminal
5.External battery connector 14.AC Input/Output terminal
6.Emergency power off connector (option) 15.Battery pack output circuit breaker
7.USB port 16.Battery bank
8.Input circuit breaker 17.Rack mount hole
9.AC Input socket 18.Parallel operation port (option)
Rack Mount Online UPS Highligh
10KVA UPS Power Supply Details
UPS Power Supply FAQ
-
Can you mount a UPS vertically?
Some types of UPS can be mounted either in a vertical or horizontal position and are designed properly vent in either kind of install. If you choose to install a UPS that is not approved for a vertical installation it may overheat and fail far earlier then you would expect. A UPS by it’s nature creates a lot of heat.
-
What is a UPS Tower?
An uninterruptible power supply (UPS) is an electrical setup that provides power backup when the main power source fails. It protects hardware such as computers, telecommunication equipment, and other sensitive electronics.
-
How do you size a rack mount up?
To correctly size an uninterruptible power supply, it is important to calculate the total IT load it is to power. This can be calculated by summing the VA (Volts x Amperage) of all the individual IT devices.