Double Conversion UPS | 3000VA / 3000W | 96Vdc | 208V/220V/230V/240V | Without battery inside
Prostar PET1103 pf1 best uninterruptible power supply 3000va ups for computer is a professional commercial solution built in double conversion technology. Equipped with DSP topology, it results in high efficiency reaching 95.5% in Line Mode and even 98.5% in ECO Mode.
PET1103 uninterruptible power supply 3000va ups is the perfect solution for supplying sensitive mission critical utilities. The applications require reliability and performance from an uninterruptible power supply.
The 3000VA UPS is suitable for medium-sized computer networks, data centers, or server rooms. It features a hot-swappable battery design, which allows for easy replacement of batteries without shutting down the UPS or connected equipment.
This UPS provides continuous and clean power to your computer, server, or network equipment, even during power outages or fluctuations in the input voltage. With its true online double-conversion technology, the UPS filters out any noise or voltage spikes, ensuring that your devices receive a stable and consistent power supply.
The life of a UPS battery is dependent on many factors such as capacity, size, model, features, usage, surrounding temperature and humidity levels etc. On an average, a small to medium UPS battery has a 4 – 5-year design life with larger UPS batteries having 8 – 10 years of design life. However, it is advisable to check/ test/ discharge a UPS battery periodically for it to function in a proper manner.
If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output. Consult your generator’s manual to see if it meets these specifications.
You need to make a note of the number of gadgets that need to function in the eventuality of a power cut, and the battery backup power requirement. Additional battery capacity should always be planned keeping future expansion in mind. These pointers will help you choose the right UPS for your ideal backup power supply requirement.
MODEL | PET1103 | |
CAPACITY | 3000VA / 3000W | |
Battery Voltage | 96VDC | |
Size, D X W X H (mm) | 395 X 143 X 222 | |
Net Weight (kgs) | 6 | |
INPUT | ||
Norminal Voltage | 208/220/230/240VAC | |
Input Voltage Range | 110-300VAC | |
Frequency Range | 50Hz:44Hz~56Hz or 60Hz:54Hz~66Hz | |
Phase | Single Phase, L+N+PE | |
Power Factor | ≧ 0.99 @ nominal voltage (input voltage) | |
Harmonic Distortion | ≤4% (Linear Load), ≤5% (Non-linear Load) | |
OUTPUT | ||
Output voltage | 208/220/230/240VAC | |
AC Voltage Regulation | ± 1% (Batt. Mode) | |
Frequency Range(Line Mode) | Synchronized range | |
Frequency Range (Batt. Mode) | 50 Hz or 60Hz ± 0.1% | |
Overload Capacity | AC Mode: Battery Mode: 30mins @102%-110% load 1min @102%-110% load 10mins @110%-130% load 10sec @110%-130% load 30sec @130%-150% load 3sec @110%-130% load 200ms @>150% load 200ms @>150% load |
|
Current Crest Ratio | 3:1 | |
Harmonic Distortion | ≦3% THD (Linear Load);≦5% THD (Non-linear Load) | |
Transfer Time | AC Mode to Battery Mode | 0ms |
Inverter to Bypass | 4ms | |
Waveform (Batt. Mode) | Pure Sine Wave | |
EFFICIENCY | ||
AC Mode | 95.5% | |
Battery Mode | 91.5% | |
BATTERY | ||
Battery Type | Depending on applications | |
Battery Numbers | 8 PCS | |
Charging Current | 5A(Default),1A-12A adjustable | |
Charging Voltage | 109.6VDC ± 1% | |
Charging Mode | 2-stage or 3-stage | |
INDICATORS | ||
LCD Panel | Load level, Battery level, AC mode, Battery mode, Bypass mode,and Fault condictions | |
ENVIRONMENT | ||
Ambient temperature | 0- 40°C | |
Operation Humidity | 20%-95% (non-condensing) | |
Storage temperature | -15~60℃ (no battery inside) | |
Altitude | <1000m ( the height above 1000m should be reduced to a maximum of 4000m.) | |
Noise Level | Less than 50dBA @ 1 Meter | |
COMMUNICATION | ||
Communication Inteface | Standard: RS232, USB; Option: Dry contact, EPO | |
Smart Slot | Optional SNMP Card |