Double Conversion UPS | 6KVA / 6KW | 192Vdc | 208V/220V/230V/240V | Built-in 16 x12V7AH UPS battery
Prostar PET1106B best double conversion online ups 6kva for desktop computers provides much stronger protection on inrush current and it improves it’s adaptability to grid power condition.
PET1106B double conversion online ups 6kva offers complete power protection for critical network applications.
Double conversion online UPS 6KVA features a user-friendly interface that allows for easy monitoring and control of the unit’s status and parameters. This includes real-time monitoring of input/output voltage, frequency, and load level, as well as the ability to configure the unit’s settings to meet your specific requirements.
A battery is a device that stores energy, a UPS detects when there is no longer any power coming from the mains and switches over to the UPS batteries.
A non-critical load, is an electrical device or devices, that aren’t key to keeping a business running or won’t be damaged by a power cut. In short, it doesn’t matter if these device lose power in an outage.
If the power requirement is low and the UPS is overrated, possibly, but normally running a UPS for this long requires so many UPS batteries it becomes unfeasible both financial and physically. It would be best to run a standby generator alongside your UPS to achieve this.
MODEL | PET1106B | |
CAPACITY | 6000VA / 6000W | |
Battery Voltage | 192VDC | |
Size, D X W X H (mm) | 475 X 190 X 696 | |
Net Weight (kgs) | 53 | |
INPUT | ||
Norminal Voltage | 208/220/230/240VAC | |
Input Voltage Range | 110-300VAC | |
Frequency Range | 50Hz:44Hz~56Hz or 60Hz:54Hz~66Hz | |
Phase | Single Phase, L+N+PE | |
Power Factor | ≧ 0.99 | |
Harmonic Distortion | ≤5% (Linear Load), ≤8% (Non-linear Load) | |
OUTPUT | ||
Output voltage | 208/220/230/240VAC | |
AC Voltage Regulation | ± 1% (Batt. Mode) | |
Frequency Range(Line Mode) | Synchronized range | |
Frequency Range (Batt. Mode) | 50 Hz or 60Hz ± 0.1% | |
Overload Capacity | AC Mode: Battery Mode: 30mins @102%-110% load 10mins @102%-110% load 10mins @110%-130% load 1min @110%-130% load 30sec @130%-150% load 10sec @110%-130% load 500ms @>150% load 500ms @>150% load |
|
Current Crest Ratio | 3:1 | |
Harmonic Distortion | ≦2% THD (Linear Load);≦5% THD (Non-linear Load) | |
Transfer Time | AC Mode to Battery Mode | 0ms |
Inverter to Bypass | 0ms | |
Waveform (Batt. Mode) | Pure Sine Wave | |
EFFICIENCY | ||
AC Mode | 95.5% | |
Battery Mode | 95.3% | |
BATTERY | ||
Battery Type | Sealed Maintenance-free | |
Battery Numbers | 16PCS x 12V7AH | |
Charging Current | 1A(Default),1A-4A adjustable | |
Charging Voltage | 219.2VDC ± 1% | |
Charging Mode | 2-stage or 3-stage | |
INDICATORS | ||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault condictions | |
ENVIRONMENT | ||
Ambient temperature | 0- 40°C | |
Operation Humidity | 20%-95% (non-condensing) | |
Storage temperature | -15~60℃ (no battery inside) | |
Altitude | <1000m ( the height above 1000m should be reduced to a maximum of 4000m.) | |
Noise Level | Less than 50dBA @ 1 Meter | |
COMMUNICATION | ||
Communication Inteface | Standard: RS232, USB; Option: Dry contact, EPO | |
Smart Slot | Optional SNMP Card |