Hybrid Solar Inverter | 10KW | IP65 | 40VDC - 60VDC | Single Phase
Prostar PHYD10K IP65 best 48v hybrid solar inverter 10kw single phase is a versatile and reliable solution for a wide range of applications. It can be integrated into electric vehicle charging infrastructure, offering a sustainable and cost-effective solution for EV owners.
The hybrid solar inverter 10kw supports various power sources, including lithium batteries, mains voltage, and generators, offering flexibility for different setups and applications. requirements.
Enables configurable settings for AC/solar/generator charger priority and adjustable battery charging parameters tailored to individual application needs. It is suitable for community-based solar energy projects, providing clean and reliable power to multiple households or facilities.
Pure Sine Wave AC Power Output
Providing clean and stable AC power, the pure sine wave output ensures that all connected devices, including sensitive electronics, operate smoothly without risk of damage.
Self-consumption and Feed-in to the Grid
Promotes self-consumption of generated solar power while allowing surplus energy to be fed back into the grid.
IP65 Protection
Weather-resistant design for reliable outdoor installation, providing protection against dust and water ingress.
On/Off Grid Capability
The hybrid solar inverter offers seamless integration into both grid-connected and standalone systems, providing you with the flexibility to switch between modes as required. This dual functionality ensures that you have continuous power supply, even in the event of grid outages.
Wide PV Input Voltage Range
Accommodating a broad range of photovoltaic input voltages, the inverter can be connected to various types of solar panels for versatile installation options.
Supply Priority Configuration
Set the priority for power supply from either the battery or the grid, allowing for customized management of your energy resources.
Adjustable Charging Parameters
Tailor the battery charging parameters according to your specific application needs directly through the LCD settings, ensuring optimal battery health and performance.
Peak Shaving
The inverter’s peak shaving feature helps manage demand charges by using stored energy during peak rate hours, reducing reliance on the grid and saving on electricity bills.
Basic Working Mode
Generator Working Mode
Smart Load Working Mode
AC Couple Working Mode
Cost Savings
Energy Independence
Enhanced Flexibility
Customization and Control
Enhanced Power Quality
Model | PHYD10K |
PHASE | 1-phase in/1-phase out |
Max. PV INPUT POWER | 13000W |
Rated Output Power | 10KW |
Parallel Function | up to 16 units |
Dimension, D x W x H (mm) | 258x413x630 |
Net weight (kgs) | 31 |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 370VDC / 500VDC |
Start-up Voltage | 125VDC |
MPPT Voltage Range | 150VDC~425VDC |
Full load MPPT Voltage Range | 200VDC~425VDC |
Max. DC INPUT Current | 26A + 26A + 26A |
Max. DC Short-circuit Current | 44A + 44A + 44A |
No. of MPPT Trackers | 3 |
No. of String per MPPT Tracker | 2 + 2 + 2 |
GRID OUTPUT (AC) | |
Rated Output Power | 10KW |
Max. AC Output Power | 11KW |
Nominal Output Voltage | 220/230/240VAC |
Output Frequency | 50Hz / 60Hz |
Rated AC Output Current | 45.5A / 43.5A |
Max. AC Output Current | 50.0A / 47.9A |
Max. Continuous AC Passthrough | 60A |
Power Factor | 0.8 leading ~ 0.8 lagging |
Total Harmonic Distortion(THDi) | < 3% |
DC Current Injection | < 0.5 |
EFFICIENCY | |
Max. Efficiency (DC/AC) | 97.6% |
Euro Efficiency | 96.5% |
MPPT Efficiency | 99.0% |
BATTERY & CHARGER | |
Battery Type | Lead-acid or Lithium-ion |
Nominal DC Voltage | 40VDC – 60VDC |
Max. Charging Current | 220A |
Max. Discharging Current | 220A |
External Temperature Sensor | Yes |
Charging Curve | 3 Stages / Equalization |
Charging Strategy for Li-battery | Self-adaption to BMS |
PROTECTION | |
PV Arc Fault Protection | Yes |
PV Input Lightning Protection | Yes |
Anti-islanding Protection | Yes |
PV Input Reverse Polarity Protection | Yes |
Insulation Resistor Protection | Yes |
Residual Crrent Monitoring Unit | Yes |
Output Over Current Protection | Yes |
Output Short-circuit Protection | Yes |
Surge Protection | DC Type II / AC Type II |
Over Voltage Category | DC Type II / AC Type III |
INTERFACE | |
Communication Port | RS485/CAN, WiFi |
ENVIRONMENT | |
Operating Temperature | -40°C to 60 °C (>45 °C derating) |
Noise | < 50dB |
Protection Degree | IP65 |
Installation Style | Wall-mounted |
CERTIFICATION STANDARDS | |
Grid Regulation | IEC61727 / IEC62116, EN50549-1 |
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |