Hybrid Solar Inverter | 12KW | IP65 | 40VDC - 60VDC | Single Phase
Prostar PHYD12K IP65 pure sine wave 48v hybrid solar inverter 12kw can offer exceptional reliability and efficiency in various applications. It combines the latest advancements in renewable energy technology with versatile functionality to ensure you have access to reliable and clean electricity, whether you’re on or off the grid.
The pure sine wave 48v hybrid solar inverter 12kw supports various power sources, including lithium batteries, mains voltage, and generators, offering flexibility for different setups and applications. requirements.
Enables configurable settings for AC/solar/generator charger priority and adjustable battery charging parameters tailored to individual application needs. It is suitable for community-based solar energy projects, providing clean and reliable power to multiple households or facilities.
IP65 hybrid solar inverter 12kW allows flexibility in solar panel configurations, accommodating a wide range of solar inputs for better performance.
Pure Sine Wave AC Power Output
Providing clean and stable AC power, the pure sine wave output ensures that all connected devices, including sensitive electronics, operate smoothly without risk of damage.
Self-consumption and Feed-in to the Grid
Promotes self-consumption of generated solar power while allowing surplus energy to be fed back into the grid.
IP65 Protection
Weather-resistant design for reliable outdoor installation, providing protection against dust and water ingress.
On/Off Grid Capability
The hybrid solar inverter offers seamless integration into both grid-connected and standalone systems, providing you with the flexibility to switch between modes as required. This dual functionality ensures that you have continuous power supply, even in the event of grid outages.
Wide PV Input Voltage Range
Accommodating a broad range of photovoltaic input voltages, the inverter can be connected to various types of solar panels for versatile installation options.
AC Coupling for Retrofit
Easily integrate with existing solar systems through AC coupling.
Parallel Operation
For larger installations, up to 16 units can be connected in parallel, significantly increasing the total system capacity for both on-grid and off-grid applications.
Peak Shaving
The inverter’s peak shaving feature helps manage demand charges by using stored energy during peak rate hours, reducing reliance on the grid and saving on electricity bills.
Diesel Generator Energy Storage
The inverter also supports the storage of energy from a diesel generator, providing an alternative source of power during extended periods of low sunlight.
Basic Working Mode
Generator Working Mode
Smart Load Working Mode
AC Couple Working Mode
Residential Solar Systems
Commercial and Industrial Installations
Remote and Off-Grid Locations
Backup Power Systems
Peak Shaving and Energy Management
Model | PHYD12K |
PHASE | 1-phase in/1-phase out |
Max. PV INPUT POWER | 15600W |
Rated Output Power | 12KW |
Parallel Function | up to 16 units |
Dimension, D x W x H (mm) | 258x413x630 |
Net weight (kgs) | 31 |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 370VDC / 500VDC |
Start-up Voltage | 125VDC |
MPPT Voltage Range | 150VDC~425VDC |
Full load MPPT Voltage Range | 200VDC~425VDC |
Max. DC INPUT Current | 26A + 26A + 26A |
Max. DC Short-circuit Current | 44A + 44A + 44A |
No. of MPPT Trackers | 3 |
No. of String per MPPT Tracker | 2 + 2 + 2 |
GRID OUTPUT (AC) | |
Rated Output Power | 12KW |
Max. AC Output Power | 13.2KW |
Nominal Output Voltage | 220/230/240VAC |
Output Frequency | 50Hz / 60Hz |
Rated AC Output Current | 54.6A / 52.2A |
Max. AC Output Current | 60.0A / 57.4A |
Max. Continuous AC Passthrough | 60A |
Power Factor | 0.8 leading ~ 0.8 lagging |
Total Harmonic Distortion(THDi) | < 3% |
DC Current Injection | < 0.5 |
EFFICIENCY | |
Max. Efficiency (DC/AC) | 97.6% |
Euro Efficiency | 96.5% |
MPPT Efficiency | 99.0% |
BATTERY & CHARGER | |
Battery Type | Lead-acid or Lithium-ion |
Nominal DC Voltage | 40VDC – 60VDC |
Max. Charging Current | 250A |
Max. Discharging Current | 250A |
External Temperature Sensor | Yes |
Charging Curve | 3 Stages / Equalization |
Charging Strategy for Li-battery | Self-adaption to BMS |
PROTECTION | |
PV Arc Fault Protection | Yes |
PV Input Lightning Protection | Yes |
Anti-islanding Protection | Yes |
PV Input Reverse Polarity Protection | Yes |
Insulation Resistor Protection | Yes |
Residual Crrent Monitoring Unit | Yes |
Output Over Current Protection | Yes |
Output Short-circuit Protection | Yes |
Surge Protection | DC Type II / AC Type II |
Over Voltage Category | DC Type II / AC Type III |
INTERFACE | |
Communication Port | RS485/CAN, WiFi |
ENVIRONMENT | |
Operating Temperature | -40°C to 60 °C (>45 °C derating) |
Noise | < 50dB |
Protection Degree | IP65 |
Installation Style | Wall-mounted |
CERTIFICATION STANDARDS | |
Grid Regulation | IEC61727 / IEC62116, EN50549-1 |
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |