PHYD30K-3P-HV IP65 3 phase high voltage hybrid solar inverter 30kw

Hybrid Solar Inverter | 30KW | IP65 | 160VDC - 700VDC | Lithium-ion Battery | Three Phase

SKU: PHYD30K-3P-HV Category:

Prostar PHYD30K-3P-HV IP65 3 phase high voltage hybrid solar inverter 30kw is engineered to optimize energy usage and enhance efficiency in various power scenarios.

When AC power is restoring after a power outage, the 3 phase high voltage hybrid solar inverter 30kw automatically restarts to ensure continuous operation and minimal disruption.

Users can set preferences for power sourcing, allowing them to prioritize battery discharge over grid consumption or vice versa based on specific needs or energy costs.

The hybrid solar inverter 30kw’s ability to work on and off the grid ensures uninterrupted power supply and enhances system flexibility. Customize the supply priority based on your needs, whether it’s the battery or the grid, for optimal energy management.

PHYD30K-3P-HV IP65 3 phase high voltage hybrid solar inverter 30kw

Hybrid Solar Inverter 30kW Features

Three-Phase Operation

Designed for three-phase grid connection, ensuring stable power supply and compatibility with most commercial and industrial electrical systems.

High Voltage Battery

The high-voltage battery system ensures greater efficiency and better performance in storing and distributing energy.

Advanced Battery Management

Optimize battery charging and discharging with up to 6 programmable time periods, ensuring efficient energy usage and longer battery life.

Parallel Operation

The inverter can be paralleled up to 10 units for both on-grid and off-grid operations, allowing for scalable solutions in larger power installations.

Peak Shaving

Support peak shaving, allowing users to reduce energy costs by managing and minimizing peak demand charges.

100% Three-Phase Unbalanced Output

Full support for unbalanced output across all three phases ensures stable and reliable power delivery even under varying loads.

IP65 Protection

With its IP65-rated enclosure, it is resistant to dust, water, and other environmental factors, making it suitable for both indoor and outdoor installations.

AC Coupling for Retrofit

The inverter can be used to retrofit existing solar systems with AC coupling, enhancing the performance of older installations.

Diesel Generator Energy Storage

It supports storing energy generated by a diesel generator, offering additional flexibility in hybrid energy systems.

Hybrid Solar Inverter Diagram

IP65 3 Phase Hybrid Solar Inverter Diagram Connection

 

Best Hybrid Inverter Overviews

Prostar IP65 HV 3 Phase Hybrid Solar Inverter 30KW-50KW Connection

Prostar IP65 HV 3 Phase Hybrid Solar Inverter 30KW-40KW Rear

 

CT Sensor Connection

Connecting a Current Transformer (CT) sensor to an IP65 3-phase hybrid solar inverter is an important step for accurately measuring the current flowing through the system, which in turn allows for precise energy management and monitoring.

Prostar IP65 3 Phase Hybrid Solar Inverter CT Connection

 

Ensure that the CT connected to the live wire of Phase 1 is connected to CT1 input on the inverter, CT for Phase 2 to CT2, and CT for Phase 3 to CT3.

Energy Meter Installation Wiring Diagram

#1. CHINT Meter Wiring

Prostar IP65 3 Phase Hybrid Solar Inverter CHINT Meter Connection

 

#2. Eastron Meter Wiring

Prostar IP65 3 Phase Hybrid Solar Inverter Eastron Meter Connection

 

Parallel Connection

For the high battery voltage hybrid solar inverter in parallel operation, the lead-acid battery is not supported. Please use approved lithium battery.

Parallel operation requires precise voltage matching and synchronization between batteries. Lithium batteries are usually more consistent in their voltage output, making them better suited for this type of operation.

Prostar IP65 3 Phase Hybrid Solar Inverter Parallel Connection

Prostar IP65 3 Phase Hybrid Solar Inverter Parallel Connection Set

 

Applications of  3 Phase Hybrid Solar Inverter

Commercial and Industrial Energy Solutions

  • Medium to Large-Scale Solar Installations: The 30kW capacity and scalability through parallel operation make it suitable for medium to large commercial or industrial solar installations, such as factories, warehouses, and office buildings.
  • Peak Shaving: Businesses can use the inverter to reduce peak demand charges by managing power consumption during peak periods.
  • Backup Power Systems: Ideal for providing uninterrupted power in commercial buildings where consistent energy supply is critical.

Rural and Remote Areas

  • Off-Grid Power Supply: In regions without reliable grid access, the inverter’s off-grid capabilities allow for the creation of standalone solar power systems that can operate independently.
  • Microgrid Solutions: You can use this solution to create microgrids in rural or remote communities that lack grid infrastructure..
  • Diesel Generator Integration: The ability to store energy from diesel generators ensures backup power availability in remote areas where solar generation alone may not be sufficient.

Residential Applications

  • Large Residential Solar Systems: The inverter’s high power output and ability to connect multiple batteries in parallel make it an excellent choice for large residential solar systems, especially in households with high energy demands.
  • Energy Independence: Homeowners can achieve greater energy independence by combining self-consumption with the ability to feed excess power back into the grid.

Agriculture and Farming

  • Solar Power for Farms: Farmers can benefit from the inverter’s ability to handle unbalanced loads and integrate with existing solar systems, providing reliable energy for irrigation, refrigeration, and other essential farm operations.
  • Energy Storage Solutions: The ability to store solar energy for use during non-sunlight hours or when solar production is low ensures that farms remain powered at all times.

Energy Resilience and Disaster Recovery

  • Backup Power During Disasters: The inverter’s hybrid capabilities ensure that solar energy can be stored and used during grid outages, making it a valuable asset in disaster recovery efforts.
  • Emergency Shelters: Providing reliable power for emergency shelters and other temporary facilities during disasters ensures critical services remain operational.

 

The Articles You may Like

Model PHYD30K-3P-HV
PHASE 3-phase in/ 3-phase out
Max. PV INPUT POWER 39000W
Rated Output Power 30KW
Parallel Function up to 10 units
Dimension, Wx D x H (mm) 527x294x894
Net weight (kgs) 80
PV INPUT (DC)
Nominal DC Voltage/Max. DC Voltage 600VDC / 1000VDC
Start-up Voltage 180VDC
MPPT Voltage Range 150VDC~850VDC
Max. DC INPUT Current 36A+36A+36A
Max. DC Short-circuit Current 55A+55A+55A
No. of MPPT Trackers 3
No. of String per MPPT Tracker 2+2+2
GRID OUTPUT (AC)
Rated Output Power 30KW
Max. AC Output Power 33KW
Nominal Output Voltage 380/400/415VAC
Output Frequency 50Hz / 60Hz
Rated AC Output Current 45.6A
Max. AC Output Current 50.2A
Max. Unbalanced Output Current 60A
Max. Continuous AC Passthrough 118A
Power Factor 0.8 leading ~ 0.8 lagging
Total Harmonic Distortion(THDi) ≤1.5% (Linear Load), ≤3% (Non-linear Load)
DC Current Injection < 0.5
EFFICIENCY
Max. Efficiency (DC/AC) 97.6%
Euro Efficiency 97.0%
MPPT Efficiency 99.9%
BATTERY & CHARGER
Battery Type Lithium-ion
Nominal DC Voltage 160VDC – 700VDC
Max. Charging Current 50A + 50A
Max. Discharging Current 50A + 50A
Battery Input Numbers 2
Charging Curve 3 Stages / Equalization
Charging Strategy for Li-battery Self-adaption to BMS
PROTECTION
PV Arc Fault Protection Yes
PV Input Lightning Protection Yes
Anti-islanding Protection Yes
PV Input Reverse Polarity Protection Yes
Insulation Resistor Protection Yes
Residual Crrent Monitoring Unit Yes
Output Over Current Protection Yes
Output Short-circuit Protection Yes
Surge Protection DC Type II / AC Type II
Over Voltage Category DC Type II / AC Type III
INTERFACE
Communication Port RS485/CAN, WiFi
ENVIRONMENT
Operating Temperature -40°C to 60 °C (>45 °C derating)
Noise < 50dB
Protection Degree IP65
Installation Style Wall-mounted
CERTIFICATION STANDARDS
Grid Regulation IEC61727 / IEC62116, EN50549-1
Safety EMC / Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2